Configuring Windows Event Forwarding

Note

The Azure ATP sensor automatically reads events locally, without the need to configure event forwarding.

To enhance detection capabilities, Azure ATP needs the following Windows events: 4776, 4732, 4733, 4728, 4729, 4756, 4757, and 7045. These can either be read automatically by the Azure ATP sensor or in case the Azure ATP sensor is not deployed, it can be forwarded to the Azure ATP standalone sensor in one of two ways, by configuring the Azure ATP standalone sensor to listen for SIEM events or by configuring Windows Event Forwarding.

Note

Check that the domain controller is properly configured to capture the required events.

WEF configuration for Azure ATP standalone sensor's with port mirroring

After you configured port mirroring from the domain controllers to the Azure ATP standalone sensor, follow the following instructions to configure Windows Event forwarding using Source Initiated configuration. This is one way to configure Windows Event forwarding.

Step 1: Add the network service account to the domain Event Log Readers Group.

In this scenario, assume that the Azure ATP standalone sensor is a member of the domain.

  1. Open Active Directory Users and Computers, navigate to the BuiltIn folder and double-click Event Log Readers.
  2. Select Members.
  3. If Network Service is not listed, click Add, type Network Service in the Enter the object names to select field. Then click Check Names and click OK twice.

After adding the Network Service to the Event Log Readers group, reboot the domain controllers for the change to take effect.

Step 2: Create a policy on the domain controllers to set the Configure target Subscription Manager setting.

Note

You can create a group policy for these settings and apply the group policy to each domain controller monitored by the Azure ATP standalone sensor. The following steps modify the local policy of the domain controller.

  1. Run the following command on each domain controller: winrm quickconfig

  2. From a command prompt type gpedit.msc.

  3. Expand Computer Configuration > Administrative Templates > Windows Components > Event Forwarding

    Local policy group editor image

  4. Double-click Configure target Subscription Manager.

    1. Select Enabled.
    2. Under Options, click Show.
    3. Under SubscriptionManagers, enter the following value and click OK: Server= http://<fqdnATPSensor>:5985/wsman/SubscriptionManager/WEC,Refresh=10` (For example: Server=http://atpsensor9.contoso.com:5985/wsman/SubscriptionManager/WEC,Refresh=10)

    Configure target subscription image

  5. Click OK.

  6. From an elevated command prompt type gpupdate /force.

Step 3: Perform the following steps on the Azure ATP standalone sensor

  1. Open an elevated command prompt and type wecutil qc

  2. Open Event Viewer.

  3. Right-click Subscriptions and select Create Subscription.

    1. Enter a name and description for the subscription.
    2. For Destination Log, confirm that Forwarded Events is selected. For Azure ATP to read the events, the destination log must be Forwarded Events.
    3. Select Source computer initiated and click Select Computers Groups.
      1. Click Add Domain Computer.
      2. Enter the name of the domain controller in the Enter the object name to select field. Then click Check Names and click OK.
      3. Click OK. Event Viewer image
    4. Click Select Events.
      1. Click By log and select Security.
      2. In the Includes/Excludes Event ID field type the event number and click OK. For example, type 4776, like in the following sample:
        Query filter image
    5. Right-click the created subscription and select Runtime Status to see if there are any issues with the status.
    6. After a few minutes, check to see that the events you set to be forwarded is showing up in the Forwarded Events on the Azure ATP standalone sensor.

For more information, see: Configure the computers to forward and collect events

See Also