Deploy host networking with Network ATC

Applies to: Azure Stack HCI, version 21H2

This article guides you through the requirements, best practices, and deployment of Network ATC. Network ATC simplifies the deployment and network configuration management for Azure Stack HCI clusters. This provides an intent-based approach to host network deployment. By specifying one or more intents (management, compute, or storage) for a network adapter, you can automate the deployment of the intended configuration. For more information on Network ATC, including an overview and definitions, see Network ATC overview.

If you have feedback or encounter any issues, review the Requirements and best practices section, check the Network ATC event log, and work with your Microsoft support team.

Requirements and best practices

The following are requirements and best practices for using Network ATC in Azure Stack HCI:

  • Supported on Azure Stack HCI, version 21H2 or later.

  • All servers in the cluster must be running Azure Stack HCI, version 21H2.

  • Must use two or more physical host systems that are Azure Stack HCI certified.

  • Adapters in the same Network ATC intent must be symmetric (of the same make, model, speed, and configuration) and available on each cluster node. For more information on adapter symmetry, see Switch Embedded Teaming (SET)

  • Each physical adapter specified in an intent, must use the same name on all nodes in the cluster.

  • Ensure each network adapter has an "Up" status, as verified by the PowerShell Get-NetAdapter cmdlet.

  • Install features from Step 1.3: Install roles and features.

  • Best practice: Insert each adapter in the same PCI slot(s) in each host. This leads to ease in automated naming conventions by imaging systems.

  • Best practice: Configure the physical network (switches) prior to Network ATC including VLANs, MTU, and DCB configuration. See Physical Network Requirements for more information.

Important

Deploying Network ATC in virtual environments is not supported. Several of the host networking properties it configures are not available in virtual machines, which will result in errors.

Common Network ATC commands

There are several new PowerShell commands included with Network ATC. Run theGet-Command -ModuleName NetworkATC cmdlet to identify them. Ensure PowerShell is run as an administrator.

Typically, only a few of these cmdlets are needed. Here is a brief overview of the cmdlets before you start:

PowerShell command Description
Add-NetIntent Creates and submits an intent
Set-NetIntent Modifies an existing intent
Get-NetIntent Gets a list of intents
Get-NetIntentStatus Gets the status of intents
Update-NetIntentAdapter Updates the adapters managed by an existing intent
Remove-NetIntent Removes an intent from the local node or cluster. This does not destroy the invoked configuration.
Set-NetIntentRetryState This command instructs Network ATC to try implementing the intent again if it has failed after three attempts. (Get-NetIntentStatus = 'Failed').

You can also modify the default configuration Network ATC creates using overrides. To see a list of possible override commandlets, use the following command:

Get-Command -Noun NetIntent*Over* -Module NetworkATC

For more information on overrides, see Update an intent override.

Example intents

Network ATC modifies how you deploy host networking, not what you deploy. Multiple scenarios may be implemented so long as each scenario is supported by Microsoft. Here are some examples of common deployment options, and the PowerShell commands needed. These are not the only combinations available but they should give you an idea of the possibilities.

For simplicity we only demonstrate two physical adapters per SET team, however it is possible to add more. Refer to Plan Host Networking for more information.

Fully converged intent

For this intent, compute, storage, and management networks are deployed and managed across all cluster nodes.

Fully converged intent

Add-NetIntent -Name ConvergedIntent -Management -Compute -Storage -ClusterName HCI01 -AdapterName pNIC01, pNIC02

Converged compute and storage intent; separate management intent

Two intents are managed across cluster nodes. Management uses pNIC01, and pNIC02; Compute and storage are on different adapters.

Storage and compute converged intent

Add-NetIntent -Name Mgmt -Management -ClusterName HCI01 -AdapterName pNIC01, pNIC02
Add-NetIntent -Name Compute_Storage -Compute -Storage -ClusterName HCI01 -AdapterName pNIC03, pNIC04

Fully disaggregated intent

For this intent, compute, storage, and management networks are all managed on different adapters across all cluster nodes.

Fully disaggregated intent

Add-NetIntent -Name Mgmt -Management -ClusterName HCI01 -AdapterName pNIC01, pNIC02
Add-NetIntent -Name Compute -Compute -ClusterName HCI01 -AdapterName pNIC03, pNIC04
Add-NetIntent -Name Storage -Storage -ClusterName HCI01 -AdapterName pNIC05, pNIC06

Storage-only intent

For this intent, only storage is managed. Management and compute adapters are not be managed by Network ATC.

Storage only intent

Add-NetIntent -Name Storage -Storage -ClusterName HCI01 -AdapterName pNIC05, pNIC06

Compute and management intent

For this intent, compute and management networks are managed, but not storage.

Management and compute intent

Add-NetIntent -Name Management_Compute -Management -Compute -ClusterName HCI01 -AdapterName pNIC01, pNIC02

Multiple compute (switch) intent

For this intent, multiple compute switches are managed.

Multiple switches intent

Add-NetIntent -Name Compute1 -Compute -ClusterName HCI01 -AdapterName pNIC03, pNIC04
Add-NetIntent -Name Compute2 -Compute -ClusterName HCI01 -AdapterName pNIC05, pNIC06

Default Network ATC values

This section lists some of the key default values used by Network ATC.

Default VLANs

The following default VLANs are used. These VLANs must be available on the physical network for proper operation.

Adapter Intent Default Value
Management Configured VLAN for management adapters isn't modified
Storage Adapter 1 711
Storage Adapter 2 712
Storage Adapter 3 713
Storage Adapter 4 714
Storage Adapter 5 715
Storage Adapter 6 716
Storage Adapter 7 717
Storage Adapter 8 718
Future Use 719

Consider the following command:

Add-NetIntent -Name Cluster_ComputeStorage -Storage -ClusterName HCI01 -AdapterName pNIC01, pNIC02, pNIC03, pNIC04

The physical NIC (or virtual NIC if required) is configured to use VLANs 711, 712, 713, and 714 respectively.

Note

Network ATC allows you to override default settings like VLANs. For examples, see Update an intent override.

Default Data Center Bridging (DCB) configuration

Network ATC establishes the following priorities and bandwidth reservations. This configuration should also be configured on the physical network.

Policy Use Default Priority Default Bandwidth Reservation
Cluster Cluster Heartbeat reservation 7 2% if the adapter(s) are <= 10 Gbps; 1% if the adapter(s) are > 10 Gbps
SMB_Direct RDMA Storage Traffic 3 50%
Default All other traffic types 0 Remainder