msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b EntityType

Entity Set Path
[organization URI]/api/data/v9.0/msdyn_bpf_477c16f59170487b8b4dc895c5dcd09bs
Base Type
crmbaseentity
Display Name
CFS - IoT Alert Process Flow
Primary Key
businessprocessflowinstanceid
Primary Key Attribute
bpf_name
Operations Supported
POST GET PATCH DELETE

Properties

Properties represent fields of data stored in the entity.Some properties are read-only.

Name Type Details
activestagestartedon Edm.DateTimeOffset

Date and time when current active stage is started

Display Name: Active Stage Started On

bpf_duration Edm.Int32

Duration of Business Process Flow

Display Name: Duration

Read Only
Is Computed
bpf_name Edm.String

Description

Display Name: Name

businessprocessflowinstanceid Edm.Guid

Unique identifier for entity instances

Display Name: CFS - IoT Alert Process Flow

completedon Edm.DateTimeOffset

Date and time when Business Process Flow instance is completed.

Display Name: Completed On

createdon Edm.DateTimeOffset

Date and time when the record was created.

Display Name: Created On

Read Only
importsequencenumber Edm.Int32

Sequence number of the import that created this record.

Display Name: Import Sequence Number

modifiedon Edm.DateTimeOffset

Date and time when the record was modified.

Display Name: Modified On

Read Only
overriddencreatedon Edm.DateTimeOffset

Date and time that the record was migrated.

Display Name: Record Created On

statecode Edm.Int32

Status of the CFS - IoT Alert Process Flow

Display Name: Status

Default Options
Value Label
0 Active
1 Inactive
statuscode Edm.Int32

Reason for the status of the CFS - IoT Alert Process Flow

Display Name: Status Reason

Default Options
Value Label
1 Active
2 Finished
3 Aborted
timezoneruleversionnumber Edm.Int32

For internal use only.

Display Name: Time Zone Rule Version Number

traversedpath Edm.String

Comma delimited string of process stage ids that represent visited stages of the Business Process Flow instance.

Display Name: Traversed Path

utcconversiontimezonecode Edm.Int32

Time zone code that was in use when the record was created.

Display Name: UTC Conversion Time Zone Code

versionnumber Edm.Int64

Version Number

Display Name: Version Number

Read Only

Lookup Properties

Lookup properties are read-only, computed properties which contain entity primary key Edm.Guid data for one or more corresponding single-valued navigation properties. More information: Lookup properties and Retrieve data about lookup properties.

Name Single-valued navigation property Description
_activestageid_value activestageid

Unique identifier of the active stage for the Business Process Flow instance.

_bpf_incidentid_value bpf_incidentid
_bpf_msdyn_iotalertid_value bpf_msdyn_iotalertid
_bpf_msdyn_workorderid_value bpf_msdyn_workorderid
_createdby_value createdby

Unique identifier of the user who created the record.

_createdonbehalfby_value createdonbehalfby

Unique identifier of the delegate user who created the record.

_modifiedby_value modifiedby

Unique identifier of the user who modified the record.

_modifiedonbehalfby_value modifiedonbehalfby

Unique identifier of the delegate user who modified the record.

_organizationid_value organizationid

Unique identifier for the organization

_processid_value processid

Unique identifier of the workflow associated to the Business Process Flow instance.

Single-valued navigation properties

Single-valued navigation properties represent lookup fields where a single entity can be referenced. Each single-valued navigation property has a corresponding partner collection-valued navigation property on the related entity.

Name Type Partner
activestageid processstage lk_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_activestageid
bpf_incidentid incident bpf_incident_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b
bpf_msdyn_iotalertid msdyn_iotalert bpf_msdyn_iotalert_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b
bpf_msdyn_workorderid msdyn_workorder bpf_msdyn_workorder_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b
createdby systemuser lk_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_createdby
createdonbehalfby systemuser lk_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_createdonbehalfby
modifiedby systemuser lk_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_modifiedby
modifiedonbehalfby systemuser lk_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_modifiedonbehalfby
organizationid organization organization_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b
processid workflow lk_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_processid

Collection-valued navigation properties

Collection-valued navigation properties represent collections of entities which may represent either a one-to-many (1:N) or many-to-many (N:N) relationship between the entities.

Name Type Partner
msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_AsyncOperations asyncoperation regardingobjectid_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b
msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_BulkDeleteFailures bulkdeletefailure regardingobjectid_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b
msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_MailboxTrackingFolders mailboxtrackingfolder regardingobjectid_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b
msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_PrincipalObjectAttributeAccesses principalobjectattributeaccess objectid_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b
msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_ProcessSession processsession regardingobjectid_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b
msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_SyncErrors syncerror regardingobjectid_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b
msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b_WorkflowLogs workflowlog asyncoperationid_msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b

Operations

The following operations can be used with the msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b entity type.

Name Binding
IsValidStateTransition Not Bound

Solutions

The following solutions include the msdyn_bpf_477c16f59170487b8b4dc895c5dcd09b entity type.

Name Description
Connected Field Service for Microsoft Dynamics 365 Use Connected Field Service to monitor connected devices to make sure your customer’s equipment is always functioning properly. If a piece of equipment fails, you’ll receive a notification, so that you can troubleshoot the problem remotely or send a technician to fix it.

See Also