2.2.2.4.4.1 Control Pause
The Control Pause order informs the receiver that the sender has paused or unpaused control.
|
|
|
|
|
|
|
|
|
|
1 |
|
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|
|
|
|
3 |
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Msg |
|||||||||||||||||||||||||||||||
|
viewerControlId |
|||||||||||||||||||||||||||||||
|
hostControlId |
|||||||||||||||||||||||||||||||
Msg (4 bytes): MUST contain either the value 0x00008003 for a pause or the value 0x00008004 for an unpause.
-
Value
Meaning
0x00008003
Pause.
0x00008004
Unpause.
viewerControlId (4 bytes): The unique identifier that is sent with the initial Take Control or Give Control Reply order.
hostControlId (4 bytes): The unique identifier that is sent with the initial Take Control Reply or Give Control order.