3.1.4.5.3 RpcAsyncDeleteMonitor (Opnum 52)

RpcAsyncDeleteMonitor removes a specified port monitor from a specified print server.

The counterpart of this method in the Print System Remote Protocol is RpcDeleteMonitor. All parameters not defined below are specified in [MS-RPRN] section 3.1.4.7.3.

 DWORD RpcAsyncDeleteMonitor(
   [in] handle_t hRemoteBinding,
   [in, string, unique] wchar_t* Name,
   [in, string, unique] wchar_t* pEnvironment,
   [in, string] wchar_t* pMonitorName
 );

hRemoteBinding: An RPC explicit binding handle.

Return Values: This method returns zero to indicate successful completion or a nonzero Win32 error code ([MS-ERREF] section 2.2) to indicate failure. The client MUST treat any nonzero return value as a fatal error.

Exceptions Thrown: This method MUST NOT throw any exceptions other than those that are thrown by the underlying RPC protocol [MS-RPCE].

This method MUST adhere to the parameter validation, processing, and response requirements that are specified in [MS-RPRN] section 3.1.4.7.3.