3.1.4.23 Application Requests Stopping Change Tracking
The application provides:
A handle to the Open identifying a VHD set.
The SVHDX_TUNNEL_OPERATION_HEADER MUST be initialized as follows:
The OperationCode MUST be set to RSVD_TUNNEL_CHANGE_TRACKING_STOP
The Status field MUST be set to zero.
The RequestId field MUST be set to RequestIdentifier.
The client MUST call the interface specified in [MS-SMB2] section 3.2.4.20.11, supplying the following input parameters:
Application-provided handle to identify the Open.
Control code: FSCTL_SVHDX_SYNC_TUNNEL_REQUEST.
SVHDX_TUNNEL_OPERATION_HEADER structure as payload.