2.2.4.1.3.14 Dial

The Dial packet is transmitted from a TAPI client to a TAPI server in a remote procedure call. Sending this packet dials the specified dialable number on the specified call.


0


1


2


3


4


5


6


7


8


9

1
0


1


2


3


4


5


6


7


8


9

2
0


1


2


3


4


5


6


7


8


9

3
0


1

Req_Func

Reserved1

dwRequestID

hCall

lpszDestAddress

dwCountryCode

Reserved2

Reserved3

Reserved4

Reserved5

Reserved6

Reserved7

Reserved8

Reserved9

Reserved10

VarData (variable)

...

Req_Func (4 bytes): An unsigned 32-bit integer. The identifier of the function that will be invoked on the remote server. This value MUST be set to 15.

Return Values

On completion of ClientRequest, this field contains the result of the encapsulated telephony request. A nonzero request ID value indicates that the request is in progress and will complete asynchronously, and a LINEERR_Constants value indicates synchronous failure.

Returns a positive request identifier if the function will be completed asynchronously or a negative error number if an error occurs. The dwParam2 parameter of the corresponding LINE_REPLY packet is zero if the function succeeds, or it is a negative error number if an error occurs. If the client specified a nonzero value in the dwRequestID field of the packet, the same value MUST be used for the returned positive request identifier. Common return values are as follows:

Name

Value

LINEERR_INVALCALLHANDLE

0x80000018

LINEERR_OPERATIONFAILED

0x80000048

LINEERR_INVALADDRESS

0x80000010

LINEERR_RESOURCEUNAVAIL

0x8000004B

LINEERR_INVALCOUNTRYCODE

0x80000022

LINEERR_DIALBILLING

0x80000008

LINEERR_INVALCALLSTATE

0x8000001C

LINEERR_DIALQUIET

0x8000000B

LINEERR_ADDRESSBLOCKED

0x80000053

LINEERR_DIALDIALTONE

0x80000009

LINEERR_NOMEM

0x80000044

LINEERR_DIALPROMPT

0x8000000A

LINEERR_OPERATIONUNAVAIL

0x80000049

Reserved1 (4 bytes): An unsigned 32-bit integer. MUST be set to zero when sent and MUST be ignored on receipt.

dwRequestID (4 bytes): An unsigned 32-bit integer. The identifier of the asynchronous request.

hCall (4 bytes): An HCALL. The handle to the call on which a number is to be dialed. One way of obtaining a valid hCall is by sending the MakeCall packet. The application MUST be an owner of the call. The call state of hCall can be any state except idle and disconnected.

lpszDestAddress (4 bytes): An unsigned 32-bit integer. The offset, in bytes, in the VarData field of a null-terminated Unicode string that specifies the destination to dial by using the standard dialable number format.

dwCountryCode (4 bytes): An unsigned 32-bit integer. The country code of the destination. The implementation uses this field to select the call-progress protocols for the destination address. If a value of 0 is specified, a default call-progress protocol that is defined by the service provider is used. TAPI does not validate this parameter when this function is called.

Reserved2 (4 bytes): An unsigned 32-bit integer. This field is used for padding and MUST be ignored on receipt. It can be any value.

Reserved3 (4 bytes): An unsigned 32-bit integer. This field is used for padding and MUST be ignored on receipt. It can be any value.

Reserved4 (4 bytes): An unsigned 32-bit integer. This field is used for padding and MUST be ignored on receipt. It can be any value.

Reserved5 (4 bytes): An unsigned 32-bit integer. This field is used for padding and MUST be ignored on receipt. It can be any value.

Reserved6 (4 bytes): An unsigned 32-bit integer. This field is used for padding and MUST be ignored on receipt. It can be any value.

Reserved7 (4 bytes): An unsigned 32-bit integer. This field is used for padding and MUST be ignored on receipt. It can be any value.

Reserved8 (4 bytes): An unsigned 32-bit integer. This field is used for padding and MUST be ignored on receipt. It can be any value.

Reserved9 (4 bytes): An unsigned 32-bit integer. This field is used for padding and MUST be ignored on receipt. It can be any value.

Reserved10 (4 bytes): An unsigned 32-bit integer. This field is used for padding and MUST be ignored on receipt. It can be any value.

VarData (variable): Contains a null-terminated Unicode string that is indicated in the lpszDestAddress field.