IWMSPublishingPoint.AllowClientsToConnect (Visual Basic .NET)

banner art

Previous Next

IWMSPublishingPoint.AllowClientsToConnect (Visual Basic .NET)

The AllowClientsToConnect property specifies and retrieves a Boolean value that indicates whether the publishing point can receive client connections.

Syntax

  IWMSPublishingPoint
  .AllowClientsToConnect = Boolean
Boolean = IWMSPublishingPoint.AllowClientsToConnect

Property Value

A Boolean indicating whether the publishing point can receive client connections. By default, this value is True.

If this property fails, it returns an error number.

Number Description
0xC00D145AL The publishing point was already removed.

Example Code

Imports Microsoft.WindowsMediaServices.Interop
Imports System.Runtime.InteropServices

Private Sub DisallowConnect()

    ' Declare variables.
    Dim Server As WMSServer
    Dim PubPoints As IWMSPublishingPoints
    Dim PubPoint As IWMSPublishingPoint
    Dim bVal As Boolean

Try
    ' Create the WMSServer object.
    Server = New WMSServer()

    ' Retrieve the IWMSPublishingPoints object.
    PubPoints = Server.PublishingPoints

    ' Retrieve information about each publishing point.
    For Each PubPoint In PubPoints

        ' Retrieve a Boolean value indicating whether
        ' clients can connect.
        bVal = PubPoint.AllowClientsToConnect

        ' Set a Boolean value indicating that
        ' clients cannot connect.
        PubPoint.AllowClientsToConnect = False
    Next

Catch excCom As COMException
    ' TODO: Handle COM exceptions.
Catch exc As Exception
    ' TODO: Handle errors.
Finally
    ' TODO: Clean-up code goes here.
End Try

End Sub

Requirements

Reference: Add a reference to Microsoft.WindowsMediaServices.

Namespace: Microsoft.WindowsMediaServices.Interop.

Assembly: Microsoft.WindowsMediaServices.dll.

Library: WMSServerTypeLib.dll.

Platform: Windows Server 2003 family, Windows Server 2008 family.

See Also

Previous Next