Share via


ARM Error Messages 151-200

The following table shows ARM error messages 151-200.

No. Error Message Warning/Error Arguments
151 improper program syntax; MEND, MEXIT directives do not have any label or prefixing text Warning  
152 improper program syntax; read error, missing MEND directive or end of file inside a macro definition Error  
153 improper program syntax; malformed macro definition (unrecoverable) Error  
154 improper program syntax; associated COMDAT section not found Error  
155 improper program syntax; attempt to redefine the associated COMDAT section; ignored Error  
156 routine name does not match the enclosing routine structure Error  
157 improper argument for <-predefine> command-line option: name expected Error  
158 improper argument for <-predefine> command-line option: %s; symbol name expected Error Command-line option
159 improper argument for <-predefine> command-line option: SETx expected Error  
160 improper argument for <-predefine> command-line option; undefined symbol in expression Error  
161 improper argument for <-predefine> command-line option: malformed or unrecognized expression Error  
162 improper argument for <-predefine> command-line option: expression type mismatch Error  
163 assembler internal error; Sync. error on ROUT areas Error  
164 assembler internal error; symbol sync. error in function symbol line numbers Error  
165 assembler internal error; address sync. error in function symbol line numbers Error  
166 assembler internal error; INCLUDE path cannot be created, check INCLUDE env. variable and <-i> command-line option Warning  
167 assembler internal error; source input sync. error; bad use of include or macros Error  
168 assembler internal error; bad input stack Error  
169 assembler internal error; bad macro structure in token input Error  
170 assembler internal error; section raw data area exceeded Error  
171 assembler internal error; PC sync error while generating literal pool Error  
172 ROUT tag of a local label does not match the enclosed ROUT name Error  
173 unknown command-line argument or argument value; error file name expected Error  
174 unknown command-line argument or argument value; include path expected Error  
175 unknown command-line argument or argument value; list file name expected    
176 unknown command-line argument or argument value; obj file name expected Error  
177 unknown command-line argument or argument value; width value expected Error  
178 unknown command-line argument or argument value; length value expected Error  
179 unknown command-line argument or argument value; SET directive expected Error  
180 unknown command-line argument or argument value; <-via> file name expected Error  
181 wrong string constant; $ character must be doubled Error  
182 attribute does not pertain to a relocatable module; ignored, weak expected Error  
183 multiple symbol definition or incompatibility; weak alias must be external Error  
184 multiple symbol definition or incompatibility; procedure name must have address 0 if it is an area COMDAT symbol Error  
185 multiple symbol definition or incompatibility; multiple definitions of section comdat symbol as function name Error  
186 multiple symbol definition or incompatibility; an assembler variable cannot be exported; export attribute deleted Error  
187 multiple symbol definition or incompatibility; a register relative symbol cannot be exported; export attribute deleted Error  
188 multiple symbol definition or incompatibility; program counter symbol cannot be exported; export attribute deleted Error  
189 multiple symbol definition or incompatibility; a string symbol cannot be exported; export attribute deleted Error  
190 multiple symbol definition or incompatibility; truncation possible on a float absolute exported symbol Error  
191 illegal symbol %s; a built-in variable cannot be used as a COMDAT symbol; ignored Error Symbol
192 illegal symbol %s; COMDAT symbol name expected Warning Symbol
193 illegal symbol %s; AREA attribute expected Error Symbol
194 illegal symbol %s; expected : '=' Error Symbol
195 illegal symbol %s; has no type Error Symbol
196 illegal symbol %s; wrong type Error Symbol
197 illegal symbol %s; absolute value expected Error Symbol
198 MEND directive before a proper macro definition Error  
199 illegal symbol %s; bad macro name Error Symbol
200 illegal symbol %s; < rgument > expected Error Symbol

See Also

ARM Guide | ARM Error Messages 1-50 | ARM Error Messages 51-100 | ARM Error Messages 101-150 | ARM Error Messages 201-250

 Last updated on Thursday, April 08, 2004

© 1992-2003 Microsoft Corporation. All rights reserved.