LocationThresholdRuleCondition Class

A rule condition based on a certain number of locations failing.

All required parameters must be populated in order to send to Azure.

Inheritance
azure.mgmt.monitor.v2015_04_01.models._models_py3.RuleCondition
LocationThresholdRuleCondition

Constructor

LocationThresholdRuleCondition(*, failed_location_count: int, data_source: Optional[azure.mgmt.monitor.v2015_04_01.models._models_py3.RuleDataSource] = None, window_size: Optional[datetime.timedelta] = None, **kwargs)

Variables

odata_type
str

Required. specifies the type of condition. This can be one of three types: ManagementEventRuleCondition (occurrences of management events), LocationThresholdRuleCondition (based on the number of failures of a web test), and ThresholdRuleCondition (based on the threshold of a metric).Constant filled by server.

data_source
<xref:$>(<xref:python-base-namespace>)RuleDataSource

the resource from which the rule collects its data. For this type dataSource will always be of type RuleMetricDataSource.

window_size
timedelta

the period of time (in ISO 8601 duration format) that is used to monitor alert activity based on the threshold. If specified then it must be between 5 minutes and 1 day.

failed_location_count
int

Required. the number of locations that must fail to activate the alert.