All Areas Reported (touchpad-all-areas-reported)

This is to test the reporting area coverage of a Windows Precision Touchpad device.

Test name

  • Test.AllAreas.json

Core requirements tested

  • Device.Input.Digitizer.PrecisionTouchpad.Accuracy

Test purpose

  • Verifies that the device can report contacts in all areas of the digitizer surface.

Tools required

  • PTLogo.exe

Validation steps

  1. Launch Test.AllAreas.json.

  2. Following the directions on the screen, you will perform 5 taps in each general region of the touchpad (top-left, top-right, bottom-left, bottom-right, and center): a. Tap anywhere inside the specified region. For example, if top-left is specified, tap anywhere left of center and above the middle of the touchpad.

i. Tap a different random location for each of the 5 iterations.

ii. If the tap occurs in the expected region, PTLogo will automatically pass the iteration.

iii. If no tap is registered for a given region, manually fail the iteration.

b. After 5 taps, the onscreen instructions will indicate the next region to tap. Repeat the preceding Step 2.a for each subsequent region as indicated. Common error messages

  • None.

Passing criteria

  • 25/25 (100%) iterations must pass in order to complete with passing status.