Selective Reporting (touchpad-selective-reporting)

This is to test the selective reporting capabilities of a Windows Precision Touchpad device.

Test name

  • Test.SelectiveReporting

Core requirements tested

  • Device.Digitizer.PrecisionTouchPad.HIDCompliance.SelectiveReporting

Test purpose

  • Verifies that the device is able to correctly respond to selective reporting requests from the host.

Tools required

  • PTLogo.exe

Validation steps

  1. Launch Test.SelectiveReporting.json as an Administrator (elevated).

  2. Move 1 contact on the touchpad, and exert activation force.

  3. Manually Pass the iteration, if the following is true (otherwise, manually Fail the iteration): then manually pass the iteration, otherwise manually fail the iteration.

The touchpad does not respond (the mouse cursor does not move, no contacts are displayed in PTLogo, and button clicks do not turn the on-screen bar green). Common error messages

  • None.

Passing criteria

  • 1/1 (100%) iterations must Pass in order to complete with passing status.