Set Energy Source Temperature Warning Threshold (Function Index 9)

This _DSM Interface for Byte Addressable Energy Backed Function Class (Function Interface 1) function sets the warning threshold for operating Energy Source (ES) temperature. This function may return a failure status if the ES is host-managed and thresholds aren't supported by the platform.

Registers are defined in the Byte Addressable Energy Backed Interface specification.

Input

Arg3

Field Byte length Byte offset Description
ES Lifetime Temperature Warning Threshold 1 0 The new value (in degrees Celsius) of the warning threshold. The platform shall write this value to the ES_TEMP_WARNING_THRESHOLD (0, 0x99) register.

Output

Field Byte length Byte offset Register Description
Status 4 0 This function can return the following Function-Specific Error Code: The platform does not support ES thresholds. For more information, see _DSM Method Output.

Set Energy Source Lifetime Warning Threshold (Function Index 8)

Get Energy Source Thresholds (Function Index 7)