Supported Storage ArraysSupported storage arrays
重要
已不再支援此版本的 Virtual Machine Manager (VMM),建議升級至 VMM 2019。This version of Virtual Machine Manager (VMM) has reached the end of support, we recommend you to upgrade to VMM 2019.
System Center - Virtual Machine Manager (VMM) 中的虛擬化工作負載,需要符合容量和效能需求的存放裝置資源。Virtualized workloads in System Center - Virtual Machine Manager (VMM) need storage resources that meet capacity and performance requirements. VMM 可以辨識本機和遠端存放裝置。VMM recognizes local and remote storage. 其支援在區塊層級存放裝置上儲存,以光纖通道、iSCSCI、SAS 連線及網路檔案共用來公開邏輯單元編號 (LUN)。It supports storage on block-level storage devices that expose logical unit numbers (LUNs) using fiber channel, iSCSCI, and SAS connections, and network file shares.
此文章提供 VMM 2016、1801、1807 支援的存放裝置清單。This article provides a list of supported storage devices for VMM 2016, 1801, 1807.
裝置Device | 通訊協定Protocol | 最低控制器韌體版本Min Controller Firmware | SMI-SSMI-S | 詳細資料Details |
---|---|---|---|---|
Hewlett Packard EnterpriseHewlett Packard Enterprise 3PAR3PAR |
SMI-SSMI-S | 3PAR: 3PAR v.3PAR: 3PAR v. 3.2.2 MU3 或更新版本3.2.2 MU3 or later 3PAR 8000 & 20000、7000 & 100003PAR 8000 & 20000, 7000 & 10000 |
SMI-S CIM 1.5 版SMI-S CIM version 1.5 | 連結Link |
TintriTintri VMstoreVMstore |
SMBSMB | 4.2 和更新版本4.2 and later | 內嵌的 2.1 版Embedded version 2.1 | 支援Support |
NEC / NEC Storage M-SeriesNEC / NEC Storage M-Series M310、M510、M710、M310F、M710F、M320、M320FM310, M510, M710, M310F, M710F, M320, M320F |
iSCSI/FCiSCSI/FC | 最低控制器韌體版本:010A (Storage Control Software Revision 0941 或更新版本)Min Controller Firmware: 010A(Storage Control Software Revision 0941 or later) | SMI-S v1.6.1SMI-S v1.6.1 | 詳細資料Details |
Fujitsu/ETERNUSFujitsu/ETERNUS DX60 S3、DX60 S4、DX100 S3、DX100 S4、DX200 S3、DX200 S4DX60 S3, DX60 S4, DX100 S3, DX100 S4, DX200 S3, DX200 S4 DX500 S3、DX500 S4、DX600 S3、 DX600 S4、DX8700 S3、DX500 S3, DX500 S4, DX600 S3, DX600 S4, DX8700 S3, DX8900 S3、DX8900 S4、DX200F、AF250、AF250 S2、AF650、AF650 S2DX8900 S3, DX8900 S4, DX200F, AF250, AF250 S2, AF650, AF650 S2 |
iSCSI/FCiSCSI/FC | V10L60 或更新版本V10L60 or later | EMBEDDED SMI-S v1.6.0EMBEDDED SMI-S v1.6.0 | 儲存體系統 ETERNUSStorage System ETERNUS |
DELL-EMCDELL-EMC XtremIO 所有快閃陣列XtremIO All Flash Array |
iSCSI/FCiSCSI/FC | XtremIO XMS Server 版本:4.2.0 和 4.2.1XtremIO XMS Server Versions: 4.2.0 and 4.2.1 | 內嵌 SMI-S V1.6.1Embedded SMI-S V1.6.1 | 連結Link |
DELLDELL SC SeriesSC Series |
iSCSI/FCiSCSI/FC | SCOS:7.2 或更新版本SCOS: 7.2 or later DSM:2016 R3 或更新版本DSM: 2016 R3 or later SCOS 7.3.5 或更新版本、DSM 2018 R1.20 或更新版本SCOS 7.3.5 or later, DSM 2018 R1.20 or later SCOS 7.4.x,DSM 2020 R1 (20.1.1) 或更新版本SCOS 7.4.x, DSM 2020 R1 (20.1.1) or later |
SMI-SSMI-S 1.6 版version 1.6 |
連結Link |
NetAppNetApp FASFAS |
iSCSI/FC/SMBiSCSI/FC/SMB | 8.2 和更新版本8.2 and later | Proxy NetApp SMIS 提供者 5.2.4 或更新版本Proxy NetApp SMIS Provider 5.2.4 or later | 連結Link |
HuaweiHuawei OceanStor V3 系列OceanStor V3 Series |
iSCSI/FCiSCSI/FC | V300R006 和更新版本V300R006 and later | Huawei SMI-SHuawei SMI-S 2.1.01 版或更新版本version 2.1.01 or later |
連結Link |
HuaweiHuawei OceanStor Dorado V3 系列OceanStor Dorado V3 Series |
iSCSI/FCiSCSI/FC | V300R001 和更新版本V300R001 and later | Huawei SMI-SHuawei SMI-S 2.1.01 版或更新版本version 2.1.01 or later |
連結Link |
HuaweiHuawei OceanStor V5 系列OceanStor V5 Series |
iSCSI/FCiSCSI/FC | V500R007 和更新版本V500R007 and later | Huawei SMI-S 提供者Huawei SMI-S Provider v 2.1.03 和更新版本v 2.1.03 and later |
TBATBA |
IBMIBM XIV Storage System Gen3XIV Storage System Gen3 |
iSCSI/FCiSCSI/FC | 11.6.0 和更新版本11.6.0 and later | 內嵌 SMI-Sembedded SMI-S v1.6.1v1.6.1 |
連結Link |
IBMIBM FlashSystem A9000/A9000RFlashSystem A9000/A9000R |
iSCSI/FCiSCSI/FC | 12.1.0 和更新版本12.1.0 and later | 內嵌 SMI-Sembedded SMI-S v1.6.1v1.6.1 |
連結Link |
IBMIBM Spectrum Virtualize 產品系列 - SAN Volume Controller(SVC)/Storwize V7000, Storwize V5000, IBM FlashSystem V9000Spectrum Virtualize Family Product - SAN Volume Controller(SVC)/Storwize V7000, Storwize V5000, IBM FlashSystem V9000 |
iSCSI/FCiSCSI/FC | 7.8.0 和更新版本7.8.0 and later | 內嵌 SMI-Sembedded SMI-S v1.6.1v1.6.1 |
連結Link |
Pure StoragePure Storage FlashArray MFlashArray M |
iSCSI/FCiSCSI/FC | Purity 4.9 和更新版本Purity 4.9 and later | SMI-SSMI-S v1.6.1v1.6.1 |
連結Link |
DELL-EMCDELL-EMC PS 系列PS Series |
iSCSIiSCSI | PS 韌體:v8.1 或更新版本PS Firmware: v8.1 or later HIT 套件:v5.1 或更新版本HIT Kit: v5.1 or later |
SMP v5.1SMP v5.1 | 連結Link |
此文章詳細說明 System Center 2019- Virtual Machine Manager (VMM) 支援的陣列。This article details the supported arrays for System Center 2019 - Virtual Machine Manager (VMM).
VMM 2019 中支援的存放裝置陣列Supported storage arrays in VMM 2019
System Center - Virtual Machine Manager (VMM) 中的虛擬化工作負載,需要符合容量和效能需求的存放裝置資源。Virtualized workloads in System Center - Virtual Machine Manager (VMM) need storage resources that meet capacity and performance requirements. VMM 可以辨識本機和遠端存放裝置。VMM recognizes local and remote storage. 其支援在區塊層級存放裝置上儲存,以光纖通道、iSCSCI、SAS 連線及網路檔案共用來公開邏輯單元編號 (LUN)。It supports storage on block-level storage devices that expose logical unit numbers (LUNs) using fiber channel, iSCSCI, and SAS connections, and network file shares.
裝置Device | 通訊協定Protocol | 最低控制器韌體版本Min Controller Firmware | SMI-SSMI-S | 詳細資料Details |
---|---|---|---|---|
Hewlett Packard EnterpriseHewlett Packard Enterprise 3PAR3PAR |
SMI-SSMI-S | 3PAR:3PAR v.3PAR: 3PAR v. 3.2.2 MU3 或更新版本3.2.2 MU3 or later 3PAR 8000 & 20000、7000 & 100003PAR 8000 & 20000, 7000 & 10000 |
SMI-S CIM 1.5 版SMI-S CIM version 1.5 | 連結Link |
NEC/NEC 儲存體 M 系列 M320、M320F、M520、M720、M720FNEC / NEC Storage M-Series M320, M320F, M520, M720, M720F | iSCSI/FCiSCSI/FC | 010A010A M320/M320F Storage Control Software 版次 1028 或更新版本M320/M320F Storage Control Software revision 1028 or later M520/M720/M720F 儲存體控制軟體修訂版 1224 或更新版本M520/M720/M720F Storage Control Software revision 1224 or later |
SMI-S 1.6.1SMI-S 1.6.1 | 連結Link |
DELLDELL SC SeriesSC Series |
iSCSI/FCiSCSI/FC | SCOS:7.4.2 或更新版本SCOS: 7.4.2 or later DSM:2019 R1 或更新版本DSM: 2019 R1 or later DSM 2020 R1 (20.1.1) 或更新版本DSM 2020 R1 (20.1.1) or later |
SMI-SSMI-S 1.6 版version 1.6 |
連結Link |
HPEHPE PrimeraPrimera |
SMI-SSMI-S | 4.0.04.0.0 | 4.0.04.0.0 | 連結Link |
注意
已知問題:透過 VMM 2019 刪除 HPE Primera 的精簡佈建存放磁碟區 (LUN) 失敗。Known issue: Deletion of thinly provisioned storage volume (LUN) fails for HPE Primera through VMM 2019.
因應措施:請直接從陣列刪除 LUN。Workaround: Delete LUN directly from the array.
後續步驟Next steps
- 深入了解在 VMM 光纖中設定存放裝置。Learn more about configuring storage in the VMM fabric.
- 深入了解陣列 SMI-S Conformance Testing Program (SMI-S CTP) (SMI-S 一致性測試計劃 (SMI-S CTP))Learn more about array SMI-S Conformance Testing Program