The update to ATA 1.7 provides improvements in the following areas:

  • New detections

  • Improvements to existing detections

Updating ATA to version 1.7

Note

If ATA is not installed in your environment, download the full version of ATA, which includes version 1.7 and follow the standard installation procedure described in Install ATA.

If you already have ATA version 1.6 deployed, this procedure walks you through the steps necessary to update your deployment.

Note

You cannot install ATA version 1.7 directly on top of ATA version 1.4 or 1.5. You must install ATA version 1.6 first.

Follow these steps to update to ATA version 1.7:

  1. Download update 1.7
    In this version of, the same installation file (Microsoft ATA Center Setup.exe) is used for installing a new deployment of ATA and for upgrading existing deployments.

  2. Update the ATA Center

  3. Update the ATA Gateways

    Important

    Update all the ATA Gateways to make sure ATA functions properly.

Step 1: Update the ATA Center

  1. Back up your database: (optional)

    • If the ATA Center is running as a virtual machine and you want to take a checkpoint, shut down the virtual machine first.

    • If the ATA Center is running on a physical server, follow the recommended procedure to back up MongoDB.

  2. Run the installation file, Microsoft ATA Center Setup.exe, and follow the instructions on the screen to install the update.

    • On the Welcome page, select your language and select Next.

    • If you didn't enable automatic updates in version 1.6, you are prompted to set ATA to use Microsoft Update for ATA to remain up-to-date. In the Microsoft Update page, select Use Microsoft Update when I check for updates (recommended). Keep ATA up-to-date image. This adjusts the Windows settings to enable updates for other Microsoft products (including ATA), as seen here. Windows auto-update image.

    • In the Data migration screen, select whether you want to migrate all or partial data. If you choose to migrate only partial data, your previously captured network traffic and behavior profiles will not be migrated. This means that it takes three weeks before the abnormal behavior detection has a complete profile to enable anomalous activity detection. During those three weeks, all other ATA detections function properly. The Partial data migration takes much less time to install. If you select Full data migration, it may take a significant amount of time for the installation to complete. The estimated amount of time and the required disk space, which are listed on the Data Migration screen, depend on the amount of previously captured network traffic you had saved in previous versions of ATA. Before selecting Partial or Full, make sure to check these requirements.

    ATA data migration.

    • Select Update. After you select Update, ATA is offline until the update procedure is complete.
  3. After the ATA Center update completes successfully, select Launch to open the Update screen in the ATA console for the ATA Gateways. Update success screen.

  4. In the Updates screen, if you already set your ATA Gateways to automatically update, they update at this point, if not, select Update next to each ATA Gateway. Update gateways image.

Important

Update all the ATA Gateways to make sure ATA functions properly. The configured Syslog listener port on all Gateways will be changed to 514.

Note

To install new ATA Gateways, go the Gateways screen and select Download Gateway Setup to get the ATA 1.7 installation package and follow the instructions for new Gateway installation as described in Step 4. Install the ATA Gateway.