3.1.4 Message Processing Events and Sequencing Rules

The ILocToLoc interface is used by client locators to forward lookup requests to master locators.

Methods in RPC Opnum Order

Method

Description

I_nsi_lookup_begin

Invoked by a client locator to enumerate the binding information for a set of RPC servers that satisfy a given set of criteria.

Opnum: 0

I_nsi_lookup_done

Invoked to free any resources associated with the context handle returned by a preceding call to the I_nsi_lookup_begin method.

Opnum: 1

I_nsi_lookup_next

Invoked to continue an enumeration of binding vectors that satisfy the criteria specified in a call to the I_nsi_lookup_begin method. The number of bindings in the binding_vector is limited by the parameter binding_max_count specified in the call to the I_nsi_lookup_begin method.

Opnum: 2

I_nsi_entry_object_inq_next

Invoked to continue an enumeration initiated by a previous call to the I_nsi_entry_object_inq_next method.

Opnum: 3

I_nsi_ping_locator

Invoked by the client to determine whether the target computer is available as a master locator.

Opnum: 4

I_nsi_entry_object_inq_done

Invoked to free any resources associated with the context handle returned by a preceding call to the I_nsi_entry_object_inq_begin method.

Opnum: 5

I_nsi_entry_object_inq_begin

Invoked to enumerate the object UUIDs on a name service entry.

Opnum: 6