Set-CsOnlineDialInConferencingUser

Use the `Set-CsOnlineDialInConferencingUser` cmdlet to modify the properties of a user that has been enabled for Microsoft's audio conferencing service.

Syntax

Set-CsOnlineDialInConferencingUser
   [[-Identity] <Object>]
   [-TenantDomain <Object>]
   [-AllowPSTNOnlyMeetings <Object>]
   [-BridgeId <Object>]
   [-BridgeName <Object>]
   [-BypassDualWrite <Object>]
   [-ConferenceId <Object>]
   [-Confirm]
   [-DomainController <Object>]
   [-Force]
   [-ResetConferenceId]
   [-ResetLeaderPin]
   [-SendEmail]
   [-SendEmailFromAddress <Object>]
   [-SendEmailFromDisplayName <Object>]
   [-SendEmailToAddress <Object>]
   [-ServiceNumber <Object>]
   [-Tenant <Object>]
   [-TollFreeServiceNumber <Object>]
   [-WhatIf]
   [-AllowTollFreeDialIn <Object>]
   [-AsJob]
   [<CommonParameters>]

Description

The Set-CsOnlineDialInConferencingUser cmdlet is used to modify properties for a Microsoft audio conferencing user. This cmdlet will not work for users with third-party conferencing providers. The cmdlet will verify that the correct license is assigned to the user.

Examples

-------------------------- Example 1 --------------------------

Set-CsOnlineDialInConferencingUser -Identity "Ken Meyers" -ConferenceId 3542699 -ResetLeaderPin -ServiceNumber 14255037265

This example shows how to set a ConferenceId for a user, reset the meeting leader's PIN and set the audio conferencing provider default meeting phone number.

-------------------------- Example 2 --------------------------

Set-CsOnlineDialInConferencingUser -Identity "Ken Meyers" -BridgeName "Conference Bridge" -ConferenceId 3542699

This example sets a user's ConferenceId and conference bridge assignment.

Optional Parameters

-AllowPSTNOnlyMeetings

If true, non-authenticated users can start meetings. If false, non-authenticated callers wait in the lobby until an authenticated user joins, thereby starting the meeting. An authenticated user is a user who joins the meeting using a Skype for Business client, or the organizer that joined the meeting via dial-in conferencing and was authenticated by a PIN number. The default is false.

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-AllowTollFreeDialIn

{{Fill AllowTollFreeDialIn Description}}

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-AsJob

{{Fill AsJob Description}}

Type:SwitchParameter
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-BridgeId

Specifies the globally-unique identifier (GUID) for the audio conferencing bridge.

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-BridgeName

Specifies the name of the audio conferencing bridge.

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-BypassDualWrite

PARAMVALUE: $true | $false

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-ConferenceId

Specifies the ConferenceId that will be used by the user for dial-in meetings. The cmdlet will fail if:

The ConferenceId is already being used in the bridge where the user is assigned, or to which the user would be assigned.

The ConferenceId doesn't meet the ConferenceId format requirements.

ConferenceId and ResetConferenceId are mutually exclusive. When ConferenceId is specified the new ConferenceId will be assigned to the user. When ResetConferenceId is specified, the user will get an auto-generated ConferenceId.

Type:Object
Aliases:Passcode
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-Confirm

The Confirm switch causes the command to pause processing and requires confirmation to proceed.

Type:SwitchParameter
Aliases:cf
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-DomainController

Specifies the domain controller that's used by the cmdlet to read or write the specified data. Valid inputs for this parameter include:

Fully qualified domain name (FQDN): -DomainController atl-cs-001.Contoso.com.

Computer name: -DomainController atl-cs-001

This parameter is reserved for internal Microsoft use.

Type:Object
Aliases:DC
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-Force

The Force switch specifies whether to suppress warning and confirmation messages. It can be useful in scripting to suppress interactive prompts. If the Force switch isn't provided in the command, you're prompted for administrative input if required.

Type:SwitchParameter
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-Identity

Specifies the Identity of the user account to be to be modified. A user identity can be specified by using one of four formats: 1) the user's SIP address; 2) the user's user principal name (UPN); 3) the user's domain name and logon name, in the form domain\logon (for example, litwareinc\kenmyer) and 4) the user's Active Directory display name (for example, Ken Myer). You can also reference a user account by using the user's Active Directory distinguished name.

Type:Object
Position:1
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-ResetConferenceId

Specifies whether to reset the ConferenceId for meetings that the user is organizing. If specified, the meetings using the old ConferenceId will fail. The user will have to reschedule his existing meetings, or run the meeting migration tool.

ConferenceId and ResetConferenceId are mutually exclusive. When ConferenceId is specified the new ConferenceId will be assigned to the user. When ResetConferenceId is specified, the user will get an auto-generated ConferenceId.

Type:SwitchParameter
Aliases:ResetPasscode
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-ResetLeaderPin

Specifies whether to reset the meeting organizer or leaders PIN for meetings.

Type:SwitchParameter
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-SendEmail

PARAMVALUE: SwitchParameter

Type:SwitchParameter
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-SendEmailFromAddress

PARAMVALUE: String

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-SendEmailFromDisplayName

PARAMVALUE: String

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-SendEmailToAddress

PARAMVALUE: String

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-ServiceNumber

Specifies the default service number for the user. The default number is used in meeting invitations. The cmdlet will verify that the service number is assigned to the user's current conference bridge, or the one the user is being assigned to.

The service number can be specified in the following formats: E.164 number, +<E.164 number> and tel:<E.164 number>.

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-Tenant

Specifies the globally unique identifier (GUID) of your Skype for Business Online tenant account. For example: -Tenant "38aad667-af54-4397-aaa7-e94c79ec2308". You can find your tenant ID by running this command: Get-CsTenant | Select-Object DisplayName, TenantID

This parameter is reserved for internal Microsoft use.

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-TenantDomain

Specifies the domain name for the tenant or organization.

This parameter is reserved for internal Microsoft use.

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-TollFreeServiceNumber

PARAMVALUE: String

Type:Object
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online
-WhatIf

The WhatIf switch causes the command to simulate its results. By using this switch, you can view what changes would occur without having to commit those changes.

Type:SwitchParameter
Aliases:wi
Position:Named
Default value:None
Accept pipeline input:False
Accept wildcard characters:False
Applies to:Skype for Business Online