IAppHostProperty::Value Property

 

Gets or sets the value of the current property.

Syntax

HRESULT get_Value(  
   [out,  
   retval] VARIANT* pVariant  
);  
HRESULT put_Value(  
   VARIANT value  
);  

Parameters

pVariant
A pointer to a VARIANT that contains the current property value.

value
A VARIANT that contains the new property value.

Return Value

An HRESULT. Possible values include, but are not limited to, those in the following table.

Value Description
S_OK Indicates that the operation was successful.

Remarks

When you set this property, the new value that is passed to the property must validate against the property schema that is assigned to the current property.

Example

The following code example disables the default document by setting the enabled attribute of the defaultDocument element to false.

#pragma once

#include <stdio.h>
#include <string.h>
#include <ahadmin.h>

int main()
{
    IAppHostWritableAdminManager * pWMgr       = NULL;
    IAppHostElement              * pParentElem = NULL;
    IAppHostPropertyCollection   * pElemProps  = NULL;
    IAppHostProperty             * pElemProp   = NULL;

    HRESULT hr                   = S_OK;
    BSTR    bstrConfigCommitPath = SysAllocString( L"MACHINE/WEBROOT/APPHOST" );
    BSTR    bstrSectionName      = SysAllocString( L"system.webServer/defaultDocument" );
    BSTR    bstrPropertyName     = SysAllocString( L"enabled" );
    VARIANT vtValue;
    vtValue.vt                   = VT_BOOL;
    vtValue.boolVal              = VARIANT_FALSE;
    VARIANT vtPropertyName;
    vtPropertyName.vt            = VT_BSTR;
    vtPropertyName.bstrVal       = bstrPropertyName;

    // Initialize
    hr = CoInitializeEx( NULL, COINIT_MULTITHREADED );
    if ( FAILED( hr ) )
    {
        printf_s( "ERROR: Unable to initialize\n" );
        goto exit;
    } 

    // Create
    hr = CoCreateInstance( __uuidof( AppHostWritableAdminManager ), NULL, 
            CLSCTX_INPROC_SERVER,
            __uuidof( IAppHostWritableAdminManager ), (void**) &pWMgr );
    if( FAILED( hr ) )
    {
        printf_s( "ERROR: Unable to create an IAppHostWritableAdminManager\n" );
        goto exit;
    }
    
    wprintf_s( L"Setting CommitPath: %s\n", bstrConfigCommitPath );
    pWMgr->put_CommitPath( bstrConfigCommitPath );

    if( FAILED( hr ) )
    {
        printf_s( "ERROR: Unable to set the commit path" );
        goto exit;
    }

    // Get the admin section
    wprintf_s( L"Getting section: %s\n", bstrSectionName );

    hr = pWMgr->GetAdminSection( bstrSectionName, bstrConfigCommitPath, &pParentElem );
    if ( FAILED( hr ) || ( &pParentElem == NULL ) )
    {
        if ( E_ACCESSDENIED == hr )
        {            
            printf_s( "ERROR: Access to configuration denied.\n" );
            printf_s( "       Run sample as an administrator.\n" );
        }
        else
        {
            printf_s( "ERROR: Unable to get configuration section.\n" );
        }
        goto exit;
    }

    // Get the property collection
    printf_s( "Getting property collection\n" );

    hr = pParentElem->get_Properties( &pElemProps );
    if ( FAILED ( hr ) || ( &pElemProps == NULL ) )
    {
        wprintf_s( L"ERROR: Unable to access attributes %s\n", bstrSectionName );
        goto exit;
    }

    // Get the property instance
    wprintf_s ( L"Getting property: %s\n", bstrPropertyName );

    hr = pElemProps->get_Item( vtPropertyName, &pElemProp );
    if ( FAILED( hr ) || ( pElemProp == NULL ) )
    {
        wprintf_s( L"ERROR: Unable to access attribute: %s\n", bstrPropertyName );
        goto exit;
    }

    // Set the property value
    wprintf_s( L"Setting property: %s to %s\n", bstrPropertyName, 
        ( vtValue.boolVal == VARIANT_TRUE ? L"true" : L"false" ) );

    hr = pElemProp->put_Value( vtValue );
    if ( FAILED( hr ) )
    {    
        wprintf_s( L"ERROR: Unable to set attribute value: %s\n", bstrPropertyName );
        goto exit;
    }

    // Commit the changes to the configuration system

    hr = pWMgr->CommitChanges();
    if( FAILED( hr ) )
    {
        printf_s( "ERROR: Unable to commit the changes to the configuration system" );
    }

exit:
    // Exiting / Unwinding
    if ( pElemProp != NULL )
    {
        pElemProp->Release();
        pElemProp = NULL;
    }
    if ( pElemProps != NULL )
    {
        pElemProps->Release(); 
        pElemProps = NULL;
    }
    if ( pParentElem != NULL )
    {
        pParentElem->Release(); 
        pParentElem = NULL;
    }
    if ( pWMgr != NULL )
    {
        pWMgr->Release(); 
        pWMgr = NULL;
    }

    SysFreeString( bstrPropertyName );
    SysFreeString( bstrConfigCommitPath );
    SysFreeString( bstrSectionName );

    // Uninitialize
    CoUninitialize();

    return 0;
};

Requirements

Type Description
Client - IIS 7.0 on Windows Vista
- IIS 7.5 on Windows 7
- IIS 8.0 on Windows 8
- IIS 10.0 on Windows 10
Server - IIS 7.0 on Windows Server 2008
- IIS 7.5 on Windows Server 2008 R2
- IIS 8.0 on Windows Server 2012
- IIS 8.5 on Windows Server 2012 R2
- IIS 10.0 on Windows Server 2016 Technical Preview
Product - IIS 7.0, IIS 7.5, IIS 8.0, IIS 8.5, IIS 10.0
- IIS Express 7.5, IIS Express 8.0, IIS Express 10.0
Header Ahadmin.h

See Also

IAppHostProperty Interface