Input Separation

This is to test the touch input separation capabilities of a Windows Touchscreen device.

Test name

InputSeparation.json Associated compatibility requirements

Device.Input.Digitizer.Touch.FingerSeparation Test purpose

Verifies that a Windows Touchscreen device meets the requirements for zoom, and multi-finger tap and swipe motions. Tools required

PT3 Running the test

Users often place their fingers close together in fast-paced games, drawing applications, musical instrument applications, and other common applications. In addition, Windows supports a system of touch gestures that let users who have low vision, fully explore the user interface (UI) and accomplish common tasks. Much of this gesture language relies on multiple fingers in close proximity.

This test consists of five scenarios that enforce the requirement that contacts in close proximity must be recognized separately. Broadly, this test verifies that a device meets these requirements during horizontal, vertical, and diagonal motion, and during a pinch gesture.

Command syntax

Logo3.exe -config InputSeparation.json Passing criteria

100% of the iterations must pass in order to complete with passing status.