Percent of machines with abnormal shutdown not due to bugcheck or power button

Description

Percent of machines with successful installations where the machine abnormally shutdown for reasons excluding bugcheck (which automatically triggers an ABS) or ungraceful power button shutdown within 3 days of install, and did not abnormally shutdown 3 days before install.

The measure aggregates telemetry from a 28-day sliding window into a ratio of machines reported abnormal shutdown within 3 days of installation / machines successfuly installed

Measure attributes

Attribute Value
Audience Retail and Insider
Time period 28 day sliding window
Measurement criteria Aggregation of machines
Minimum instances 170
Passing criteria <= 20%
Measure ID 23260722

Calculation

machines reporting abnormal shutdown within 3 days of successful installation (defined by measure 20116729), and not ABS 3 days prior /

machines successfully installing