A minifilter driver's preoperation callback routine should treat a buffer in an IRP-based I/O operation as follows:

  • Check whether an MDL exists for the buffer. The MDL pointer can be found in the MdlAddress or OutputMdlAddress parameter in the FLT_PARAMETERS for the operation. Minifilter drivers can call FltDecodeParameters to query for the MDL pointer.

    One method for obtaining a valid MDL is to look for the IRP_MN_MDL flag in the MinorFunction member of the I/O parameter block, FLT_IO_PARAMETER_BLOCK, in the callback data. The following example shows how to check for the IRP_MN_MDL flag.

    NTSTATUS status;
    PMDL *ReadMdl = NULL;
    PVOID ReadAddress = NULL;
    
    if (FlagOn(CallbackData->Iopb->MinorFunction, IRP_MN_MDL))
    {
        ReadMdl = &CallbackData->Iopb->Parameters.Read.MdlAddress;
    }
    

    However, the IRP_MN_MDL flag can be set only for read and write operations. It is best to use FltDecodeParameters to retrieve an MDL, because the routine checks for a valid MDL for any operation. In the following example, only the MDL parameter is returned if valid.

    NTSTATUS status;
    PMDL *ReadMdl = NULL;
    PVOID ReadAddress = NULL;
    
    status = FltDecodeParameters(CallbackData, &ReadMdl, NULL, NULL, NULL);
    
  • If an MDL exists for the buffer, call MmGetSystemAddressForMdlSafe to obtain the system address for the buffer and then use this address to access the buffer.

    Continuing from the previous example, the following code obtains the system address.

    if (*ReadMdl != NULL)
    {
        ReadAddress = MmGetSystemAddressForMdlSafe(*ReadMdl, NormalPagePriority);
        if (ReadAddress == NULL)
        {
            CallbackData->IoStatus.Status = STATUS_INSUFFICIENT_RESOURCES;
            CallbackData->IoStatus.Information = 0;
        }
    }
    
  • If there is no MDL for the buffer, use the buffer address to access the buffer. To ensure that a user-space buffer address is valid, the minifilter driver must use a routine such as ProbeForRead or ProbeForWrite, enclosing all buffer references in try/except blocks.

A preoperation callback routine should treat a buffer in a fast I/O operation as follows:

  • Use the buffer address to access the buffer (because a fast I/O operation cannot have an MDL).

  • To ensure that a user-space buffer address is valid, the minifilter driver must use a routine such as ProbeForRead or ProbeForWrite, enclosing all buffer references in try/except blocks.

For operations that can be fast I/O or IRP-based, all buffer references should be enclosed in try/except blocks. Although you do not have to enclose these references for IRP-based operations that use buffered I/O, the try/except blocks are a safe precaution.