iSCSI HBA Persistent Login Test (LOGO)

This test verifies the basic functionality of persistent logons and verifies that targets are logged on every time the operating system restarts.

Test details

   
Specifications
  • Device.Storage.Controller.Iscsi.Interface
Platforms
  • Windows 10, client editions (x86)
  • Windows 10, client editions (x64)
  • Windows Server 2016 (x64)
Supported Releases
  • Windows 10
  • Windows 10, version 1511
  • Windows 10, version 1607
  • Windows 10, version 1703
  • Windows 10, version 1709
  • Windows 10, version 1803
  • Windows 10, version 1809
  • Windows 10, version 1903
  • Next update to Windows 10
Expected run time (in minutes) 10
Category Development
Timeout (in minutes) 600
Requires reboot false
Requires special configuration true
Type automatic

 

Additional documentation

Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):

Running the test

Before you run the test, complete the test setup as described in the test requirements: iSCSI HBA Testing Prerequisites.

If this is the first time you are running an iSCSI HBA test, iSCSI Target test, or MPIO test over iSCSI bus type on the HLK client, or if there is no iscsihctconfig.ini under [HLK Path]\JobsWorkingDir\ on the HLK client, you will receive a pop-up dialog box to input iSCSI configuration information and/or HBA information. For more information about this dialog box, see "Running the test" in iSCSI HBA Boot Test (LOGO).

Troubleshooting

For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.

For troubleshooting information, see Troubleshooting Device.Storage Testing.

In addition:

  1. Look at the job results log file for test failures.

  2. Check if the target has a drive letter.

  3. Enter the required data in the configuration dialog box that appears when this job is scheduled. For more information, go to iSCSI HBA Boot Test (LOGO).

This test always return Pass or Fail. To review test details, review the test log from the Windows HLK Manager.

More information

This test verifies that the Microsoft iSCSI initiator service is running on the system that you are testing. The test verifies that the host-bus adapter (HBA) driver properly returns the current list of registered persistent targets. The test attempts to add a disk target to the list of current persistent targets and then verifies that the target persists after the system restarts.

The test uses an additional application that is used to access the target after the system restarts. This test application, Hitdisk.exe, must be located in the working directory of the iSCSI Persistent test program.

To run this test:

  1. Log on to the disk target and format the drive. The disk target should have a drive letter before you run the test.

  2. Run the test from the Windows HLK Studio.

  3. Enter the required data in the configuration dialog box that appears when this job is scheduled.

Command syntax

Command option Description

Iscsi_plogin.exe -phase [1|2] -hct -wtt -volumearrival [VolumeArrivalTime]

Runs the test.

Note

   For command-line help for this test binary, type /h

 

File list

File Location

Iscsi_plogin.exe

<[testbinroot]>\nttest\driverstest\storage\wdk\iscsi\

 

Parameters

Parameter name Parameter description
VolumeArrivalTime Time (in seconds) to wait for an iSCSI volume to appear after logging on
LLU_NetAccessOnly User account for accessing test fileshare.
LLU_LclAdminUsr User account for running the test.