WGF11 Fill Rules

This automated test verifies whether the device is consistent with the triangle fill rules and point fill rules as detailed in the DX11 specification.

The test draws geometry in various orientations relative to sample locations, and verifies that fill rules are observed. Test cases cycle on different formats, pixel positions, sample counts, quality levels, and sample indices. The geometry drawn can be a triangle or a point.

This topic applies to the following test jobs:

  • WGF11 Fill Rules

  • WGF11 Fill Rules (WoW64)

Test details

   
Specifications
  • Device.Graphics.AdapterRender.D3D111Core.D3D111CorePrimary
  • Device.Graphics.AdapterRender.D3D11Core.D3D11CorePrimary
  • Device.Graphics.AdapterRender.D3D101Core.D3D101CorePrimary
  • Device.Graphics.AdapterRender.D3D10Core.D3D10CorePrimary
Platforms
  • Windows 10, client editions (x86)
  • Windows 10, client editions (x64)
  • Windows Server 2016 (x64)
  • Windows 10, client editions (Arm64)
Supported Releases
  • Windows 10
  • Windows 10, version 1511
  • Windows 10, version 1607
  • Windows 10, version 1703
  • Windows 10, version 1709
  • Windows 10, version 1803
  • Windows 10, version 1809
  • Windows 10, version 1903
  • Next update to Windows 10
Expected run time (in minutes) 10
Category Compatibility
Timeout (in minutes) 600
Requires reboot false
Requires special configuration false
Type automatic

 

Additional documentation

Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):

Running the test

Before you run the test, complete the test setup as described in the test requirements: Graphic Adapter or Chipset Testing Prerequisites..

Troubleshooting

For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.

For troubleshooting information, see Troubleshooting Device.Graphics Testing.

Test cases return one of the following results:

  • Pass

  • Fail

  • Blocked

  • Skipped

The log file contains specific details about the test cases that are failed, blocked, or skipped. A test case will return Skipped if it is invalid according to the hardware configuration (some features are optional and may not be supported by some hardware) and the command line options (some test cases are only valid for certain feature levels). A test case will return Blocked if the failure is caused by reasons other than the tested feature. To review test details, review the test log from the Windows HLK Manager.

More information

.

Command syntax

Command option Description

Wgf11fillrules

Runs the test jobs. Without any options, the test enumerates devices.

-FeatureLevel:XX.X

Sets the feature level, where XX.X is the Feature Level the test will run at: 10.0, 10.1, or 11.0.

Note

   For command line help for this test binary, type /?.

 

File list

File Location

Configdisplay.exe

<[testbinroot]>\nttest\windowstest\tools\

D3d11_1sdklayers.dll

<[testbinroot]>\nttest\windowstest\graphics\d3d\support\

D3d11ref.dll

<[testbinroot]>\nttest\windowstest\graphics\d3d\support\

D3d11sdklayers.dll

<[testbinroot]>\nttest\windowstest\graphics\d3d\support\

D3dcompiler_test.dll

<[testbinroot]>\nttest\windowstest\graphics\d3d\support

D3dx10_test.dll

<[testbinroot]>\nttest\windowstest\graphics\d3d\support\

d3dx11_test.dll

<[testbinroot]>\nttest\windowstest\graphics\d3d\support\

TDRWatch.exe

<[testbinroot]>\nttest\windowstest\graphics\

Wgf11fillrules.exe

<[testbinroot]>\nttest\windowstest\graphics\d3d\conf

 

Parameters

Parameter name Parameter description
MODIFIEDCMDLINE Additional command line arguments for test executable
LLU_NetAccessOnly LLU Name of net user
ConfigDisplayCommandLine Custom Command Line for ConfigDisplay. Default: logo
TDRArgs /get or /set