Test.ReportRate (968c432e-228d-4d1b-a44e-d7213233a391)

This test verifies that the device reports at the required rate during single finger interactions.

Test details

   
Specifications
  • Device.Input.Digitizer.PrecisionTouchpad.HIDCompliant
  • Device.Input.Digitizer.PrecisionTouchpad.ReportRate
Platforms
  • Windows 10, client editions (x86)
  • Windows 10, client editions (x64)
  • Windows 10, client editions (Arm64)
Supported Releases
  • Windows 10
  • Windows 10, version 1511
  • Windows 10, version 1607
  • Windows 10, version 1703
  • Windows 10, version 1709
  • Windows 10, version 1803
  • Windows 10, version 1809
  • Windows 10, version 1903
  • Next update to Windows 10
Expected run time (in minutes) 2
Category Compatibility
Timeout (in minutes) 120
Requires reboot false
Requires special configuration false
Type automatic

 

Additional documentation

Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):

Running the test

Before you run the test, complete the test setup as described in the test requirements: Mouse or other Pointing Device Testing Prerequisites.

  1. Following the instructions on the screen, move one contact around on the touchpad for 1, 5, or 20 seconds. (a clock in the upper right corner shows how many seconds have passed since all contacts have been down).

  2. Repeat 11 times. Note that the length of time will change for some iterations, so please read and follow the on-screen instructions for each iteration

    PTLogo will fail an iteration and display an error if there is a problem with the report rate. Otherwise, the iteration will pass upon lift, and PTLogo will advance to the next iteration.

Troubleshooting

For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.

For troubleshooting information, see Troubleshooting Device.Input Testing.

More information

Command syntax

Command Description

ptlogo.exe Test.ReportRate.json

Runs the test.

 

File list

File Location

ptlogo.exe

<testbinroot>\input\PrecisionTouchpad\

config.json

<testbinroot>\input\PrecisionTouchpad\

Test.ReportRate.json

<testbinroot>\input\PrecisionTouchpad\