Msvm_FcSwitchPort class

Note

This article contains references to the term slave—a term that Microsoft doesn't condone, and has stopped using in new products and documentation. When the term is removed from the software, we’ll remove it from this article.

Represents a port on the virtual Fibre Channel switch.

The following syntax is simplified Managed Object Format (MOF) code, and it includes all of the inherited properties.

Syntax

[Dynamic, Provider("VmmsWmiInstanceAndMethodProvider"), AMENDMENT]
class Msvm_FcSwitchPort : CIM_FCPort
{
  string   InstanceID;
  string   Caption;
  string   Description;
  string   ElementName;
  datetime InstallDate;
  string   Name;
  uint16   OperationalStatus[];
  string   StatusDescriptions[];
  string   Status;
  uint16   HealthState;
  uint16   CommunicationStatus;
  uint16   DetailedStatus;
  uint16   OperatingStatus;
  uint16   PrimaryStatus;
  uint16   EnabledState = 2;
  string   OtherEnabledState;
  uint16   RequestedState = 12;
  uint16   EnabledDefault = 2;
  datetime TimeOfLastStateChange;
  uint16   AvailableRequestedStates[];
  uint16   TransitioningToState;
  string   SystemCreationClassName;
  string   SystemName;
  string   CreationClassName;
  string   DeviceID;
  boolean  PowerManagementSupported;
  uint16   PowerManagementCapabilities[];
  uint16   Availability;
  uint16   StatusInfo;
  uint32   LastErrorCode;
  string   ErrorDescription;
  boolean  ErrorCleared;
  string   OtherIdentifyingInfo[];
  uint64   PowerOnHours;
  uint64   TotalPowerOnHours;
  string   IdentifyingDescriptions[];
  uint16   AdditionalAvailability[];
  uint64   MaxQuiesceTime;
  uint64   Speed;
  uint64   MaxSpeed;
  uint64   RequestedSpeed;
  uint16   UsageRestriction;
  uint16   PortType;
  string   OtherPortType;
  string   OtherNetworkPortType;
  uint16   PortNumber;
  uint16   LinkTechnology;
  string   OtherLinkTechnology;
  string   PermanentAddress;
  string   NetworkAddresses[];
  boolean  FullDuplex;
  boolean  AutoSense;
  uint64   SupportedMaximumTransmissionUnit;
  uint64   ActiveMaximumTransmissionUnit;
  uint16   SupportedCOS[];
  uint16   ActiveCOS[];
  uint16   SupportedFC4Types[];
  uint16   ActiveFC4Types[];
};

Members

The Msvm_FcSwitchPort class has these types of members:

Methods

The Msvm_FcSwitchPort class has these methods.

Method Description
EnableDevice This method is not supported.
OnlineDevice This method is not supported.
QuiesceDevice This method is not supported.
RequestStateChange requests a state change.
Reset Resets the virtual device.
RestoreProperties This method is not supported.
SaveProperties This method is not supported.
SetPowerState This method is not supported.

Properties

The Msvm_FcSwitchPort class has these properties.

ActiveCOS

Data type: uint16 array

Access type: Read-only

An array of integers that indicates the classes of service that are active. The supported COS are specified by the SupportedCOS property. This property is inherited from CIM_FCPort.

Unknown (0)

1 (1)

2 (2)

3 (3)

4 (4)

5 (5)

6 (6)

F (7 )

ActiveFC4Types

Data type: uint16 array

Access type: Read-only

An array of integers that indicates the Fibre Channel FC-4 protocols currently running. A list of all supported protocols is specified by the SupportedFC4Types property. This property is inherited from CIM_FCPort.

Unknown (0)

Other (1)

ISO/IEC 8802 - 2 LLC (4)

IP over FC (5)

SCSI - FCP (8)

SCSI - GPP (9)

IPI - 3 Master (17)

IPI - 3 Slave (18)

IPI - 3 Peer (19)

CP IPI - 3 Master (21)

CP IPI - 3 Slave (22)

CP IPI - 3 Peer (23)

SBCCS Channel (25)

SBCCS Control Unit (26)

FC-SB-2 Channel (27)

FC-SB-2 Control Unit (28)

Fibre Channel Services (FC-GS, FC-GS-2, FC-GS-3) (32)

FC-SW (34)

FC - SNMP (36)

HIPPI - FP (64)

BBL Control (80)

BBL FDDI Encapsulated LAN PDU (81)

BBL 802.3 Encapsulated LAN PDU (82)

FC - VI (88)

FC - AV (96)

Vendor unique (255)

ActiveMaximumTransmissionUnit

Data type: uint64

Access type: Read-only

Qualifiers: Units ("Bytes")

The active or negotiated maximum transmission unit (MTU) that can be supported, in bytes. This property is inherited from CIM_NetworkPort.

AdditionalAvailability

Data type: uint16 array

Access type: Read-only

Any additional availability and status of the device. This property is inherited from CIM_LogicalDevice, but it is not used.

AutoSense

Data type: boolean

Access type: Read-only

Indicates whether the port is capable of automatically determining the speed or other communications characteristics of the attached network media. This property is inherited from CIM_NetworkPort.

Availability

Data type: uint16

Access type: Read-only

The primary availability and status of the device. This property is inherited from CIM_LogicalDevice, but it is not used.

AvailableRequestedStates

Data type: uint16 array

Access type: Read-only

Indicates the possible values for the RequestedState parameter of the RequestStateChange method. This property is inherited from CIM_EnabledLogicalElement, and it is always set to Null.

Caption

Data type: string

Access type: Read-only

A short description of the object. This property is inherited from CIM_ManagedElement.

CommunicationStatus

Data type: uint16

Access type: Read-only

Indicates the ability of the instrumentation to communicate with the underlying managed element. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.

Unknown (0)

Not Available (1)

Communication OK (2)

Lost Communication (3)

No Contact (4)

DMTF Reserved (..)

Vendor Reserved (0x8000.. )

CreationClassName

Data type: string

Access type: Read-only

The scoping system's creation class name. This property is inherited from CIM_LogicalDevice.

Description

Data type: string

Access type: Read-only

A description of the object. This property is inherited from CIM_ManagedElement.

DetailedStatus

Data type: uint16

Access type: Read-only

Compliments the PrimaryStatus property with additional status detail. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.

Not Available (0)

No Additional Information (1)

Stressed (2)

Predictive Failure (3)

Non-Recoverable Error (4)

Supporting Entity in Error (5)

DMTF Reserved (..)

Vendor Reserved (0x8000.. )

DeviceID

Data type: string

Access type: Read-only

An address or other identifying information to uniquely name the logical device. This property is inherited from CIM_LogicalDevice.

ElementName

Data type: string

Access type: Read-only

A display name for the object. This property is inherited from CIM_ManagedElement.

EnabledDefault

Data type: uint16

Access type: Read-only

An administrator's default or startup configuration for the EnabledState property of an element. This property is inherited from CIM_EnabledLogicalElement, and it is always set to 2 (Enabled).

EnabledState

Data type: uint16

Access type: Read-only

The enabled and disabled states of an element. This property is inherited from CIM_EnabledLogicalElement, and it will be one of the following values.

Value Meaning
Unknown
0
The state of the element could not be determined.
Other
1
Enabled
2
The element is running.
Disabled
3
The element is turned off.
Shutting Down
4
The element is in the process of going to a Disabled state.
Not Applicable
5
The element does not support being enabled or disabled.
Enabled but Offline
6
The element might be completing commands, and it will drop any new requests.
In Test
7
The element is in a test state.
Deferred
8
The element might be completing commands, but it will queue any new requests.
Quiesce
9
The element is enabled but in a restricted mode. The behavior of the element is similar to the Enabled state (2), but it processes only a restricted set of commands. All other requests are queued.
Starting
10
The element is in the process of going to an Enabled state (2). New requests are queued.

ErrorCleared

Data type: boolean

Access type: Read-only

Indicates whether the error reported in LastErrorCode is now cleared. This property is inherited from CIM_LogicalDevice, but it is not used.

ErrorDescription

Data type: string

Access type: Read-only

A string that provides more information about the error recorded in LastErrorCode and information about any corrective actions that can be taken. This property is inherited from CIM_LogicalDevice, but it is not used.

FullDuplex

Data type: boolean

Access type: Read-only

Indicates whether the port is operating in full duplex mode. This property is inherited from CIM_NetworkPort.

HealthState

Data type: uint16

Access type: Read-only

The current health of the element. This property is inherited from CIM_ManagedSystemElement.

IdentifyingDescriptions

Data type: string array

Access type: Read-only

An array of free-form strings that provide explanations and details behind the entries in the OtherIdentifyingInfo property array. This property is inherited from CIM_LogicalDevice, but it is not used.

InstallDate

Data type: datetime

Access type: Read-only

The date and time when the object was installed. This property does not need a value to indicate that the object is installed. This property is inherited from CIM_ManagedSystemElement.

InstanceID

Data type: string

Access type: Read-only

Qualifiers: Key

Uniquely identifies an instance of this class. This property is inherited from CIM_ManagedElement.

LastErrorCode

Data type: uint32

Access type: Read-only

The last error code reported by the logical device. This property is inherited from CIM_LogicalDevice, but it is not used.

LinkTechnology

Data type: uint16

Access type: Read-only

Specifies the type of link technology for the port. When set to 1 (Other), the OtherLinkTechnology property contains a string description of the type of link. This property is inherited from CIM_NetworkPort.

Unknown (0)

Other (1)

Ethernet (2)

IB (3)

FC (4)

FDDI (5)

ATM (6)

Token Ring (7)

Frame Relay (8)

Infrared (9)

BlueTooth (10)

Wireless LAN (11 )

MaxQuiesceTime

Data type: uint64

Access type: Read-only

This property has been deprecated. This property is inherited from CIM_LogicalDevice, but it is not used.

MaxSpeed

Data type: uint64

Access type: Read-only

Qualifiers: Units ("Bits per Second")

The maximum bandwidth of the port, in bits per second. This property is inherited from CIM_LogicalPort.

Name

Data type: string

Access type: Read-only

The label by which the object is known. This property is inherited from CIM_ManagedSystemElement.

NetworkAddresses

Data type: string array

Access type: Read-only

Qualifiers: MaxLen ( 64 )

An array of strings that contain the MAC addresses for the port. This property is inherited from CIM_NetworkPort.

OperatingStatus

Data type: uint16

Access type: Read-only

Provides current status information for the operational condition of the element and can be used for providing more detail with respect to the value of the EnabledState property. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.

Unknown (0)

Not Available (1)

Servicing (2)

Starting (3)

Stopping (4)

Stopped (5)

Aborted (6)

Dormant (7)

Completed (8)

Migrating (9)

Emigrating (10)

Immigrating (11)

Snapshotting (12)

Shutting Down (13)

In Test (14)

Transitioning (15)

In Service (16)

DMTF Reserved (..)

Vendor Reserved (0x8000.. )

OperationalStatus

Data type: uint16 array

Access type: Read-only

The current statuses of the object. This property is inherited from CIM_ManagedSystemElement.

OtherEnabledState

Data type: string

Access type: Read-only

A string that describes the enabled or disabled state of the element when the EnabledState property is set to 1 (Other). This property must be set to Null when the EnabledState property is any value other than 1. This property is inherited from CIM_EnabledLogicalElement, and it is always set to Null.

OtherIdentifyingInfo

Data type: string array

Access type: Read-only

Any additional data, beyond device ID information, that could be used to identify a logical device. This property is inherited from CIM_LogicalDevice, but it is not used.

OtherLinkTechnology

Data type: string

Access type: Read-only

A string value that describes LinkTechnology when it is set to 1, (Other). This property is inherited from CIM_NetworkPort.

OtherNetworkPortType

Data type: string

Access type: Read-only

The use of this property is deprecated in lieu of the PortType property. This property is inherited from CIM_NetworkPort.

OtherPortType

Data type: string

Access type: Read-only

Describes the type of module when PortType is set to 1 (Other). This property is inherited from CIM_LogicalPort.

PermanentAddress

Data type: string

Access type: Read-only

Qualifiers: MaxLen ( 64 )

The network address that is hardcoded into a port. This hardcoded address can be changed by using a firmware upgrade or a software configuration. When this change is made, the field should be updated at the same time. This property should be Null if no hardcoded address exists for the network adapter. This property is inherited from CIM_NetworkPort.

PortNumber

Data type: uint16

Access type: Read-only

The port number. This property is inherited from CIM_NetworkPort.

PortType

Data type: uint16

Access type: Read-only

The specific mode that is currently enabled for the port. When set to 1 (Other), the related OtherPortType property contains a string description of the type of port. This property is inherited from CIM_LogicalPort.

Unknown (0)

Other (1)

//50 Copper 10BaseT (50)

10-100BaseT (51)

100BaseT (52)

1000BaseT (53)

2500BaseT (54)

10GBaseT (55)

10GBase-CX4 (56)

//100 Fibre 100Base-FX (100)

100Base-SX (101)

1000Base-SX (102)

1000Base-LX (103)

1000Base-CX (104)

10GBase-SR (105)

10GBase-SW (106)

10GBase-LX4 (107)

10GBase-LR (108)

10GBase-LW (109)

10GBase-ER (110)

10GBase-EW (111)

Vendor Reserved (16000..65535 )

PowerManagementCapabilities

Data type: uint16 array

Access type: Read-only

The power management capabilities of the device. This property is inherited from CIM_LogicalDevice, but it is not used.

PowerManagementSupported

Data type: boolean

Access type: Read-only

Indicates whether the device can be power managed. This property is inherited from CIM_LogicalDevice, but it is not used.

PowerOnHours

Data type: uint64

Access type: Read-only

The number of consecutive hours that this device has been powered on since its last power cycle. This property is inherited from CIM_LogicalDevice, but it is not used.

PrimaryStatus

Data type: uint16

Access type: Read-only

Provides high level status information. This property should be used in conjunction with the DetailedStatus property to provide high level and detailed health status of the element and its subcomponents. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.

Unknown (0)

OK (1)

Degraded (2)

Error (3)

DMTF Reserved (..)

Vendor Reserved (0x8000.. )

RequestedSpeed

Data type: uint64

Access type: Write-only

Qualifiers: Units ("Bits per Second")

The requested bandwidth of the port, in bits per second. The actual bandwidth is reported in the Speed property. This property is inherited from CIM_LogicalPort.

RequestedState

Data type: uint16

Access type: Read-only

The last requested or desired state for the element. This property is inherited from CIM_EnabledLogicalElement, and it is always set to 12 (Not Applicable).

Speed

Data type: uint64

Access type: Read-only

Qualifiers: Units ("Bits per Second")

The bandwidth of the port, in bits per second. This property is inherited from CIM_LogicalPort.

Status

Data type: string

Access type: Read-only

The current status of the object. This property is inherited from CIM_ManagedSystemElement, but it is not used.

StatusDescriptions

Data type: string array

Access type: Read-only

Strings that describe the various OperationalStatus array values. This property is inherited from CIM_ManagedSystemElement.

StatusInfo

Data type: uint16

Access type: Read-only

The current state of the logical device. This property is inherited from CIM_LogicalDevice, but it is not used.

SupportedCOS

Data type: uint16 array

Access type: Read-only

An array of integers that indicates the Fibre Channel classes of service (COS) that are supported. The active COS are specified by the ActiveCOS property. This property is inherited from CIM_FCPort.

Unknown (0)

1 (1)

2 (2)

3 (3)

4 (4)

5 (5)

6 (6)

F (7 )

SupportedFC4Types

Data type: uint16 array

Access type: Read-only

An array of integers that indicates the Fibre Channel FC-4 protocols supported. The protocols that are active and running are specified by the ActiveFC4Types property. This property is inherited from CIM_FCPort.

Unknown (0)

Other (1)

ISO/IEC 8802 - 2 LLC (4)

IP over FC (5)

SCSI - FCP (8)

SCSI - GPP (9)

IPI - 3 Master (17)

IPI - 3 Slave (18)

IPI - 3 Peer (19)

CP IPI - 3 Master (21)

CP IPI - 3 Slave (22)

CP IPI - 3 Peer (23)

SBCCS Channel (25)

SBCCS Control Unit (26)

FC-SB-2 Channel (27)

FC-SB-2 Control Unit (28)

Fibre Channel Services (FC-GS, FC-GS-2, FC-GS-3) (32)

FC-SW (34)

FC - SNMP (36)

HIPPI - FP (64)

BBL Control (80)

BBL FDDI Encapsulated LAN PDU (81)

BBL 802.3 Encapsulated LAN PDU (82)

FC - VI (88)

FC - AV (96)

Vendor unique (255)

SupportedMaximumTransmissionUnit

Data type: uint64

Access type: Read-only

Qualifiers: Units ("Bytes")

The maximum transmission unit (MTU) that can be supported, in bytes. This property is inherited from CIM_NetworkPort.

SystemCreationClassName

Data type: string

Access type: Read-only

The scoping system's creation class name. This property is inherited from CIM_LogicalDevice.

SystemName

Data type: string

Access type: Read-only

The scoping system's name. This property is inherited from CIM_LogicalDevice.

TimeOfLastStateChange

Data type: datetime

Access type: Read-only

The date or time when the enabled state of the element last changed. This property is inherited from CIM_EnabledLogicalElement, and it is always set to Null.

TotalPowerOnHours

Data type: uint64

Access type: Read-only

The total number of hours that this device has been powered. This property is inherited from CIM_LogicalDevice, but it is not used.

TransitioningToState

Data type: uint16

Access type: Read-only

Indicates the target state to which the instance is transitioning. This property is inherited from CIM_EnabledLogicalElement, and it is always set to Null.

UsageRestriction

Data type: uint16

Access type: Read-only

In some circumstances, a logical port might be identifiable as a front end or back end port. An example of this situation would be a storage array that might have back end ports to communicate with disk drives and front end ports to communicate with hosts. If there is no restriction on the use of the port, then the value should be set to 4 (Not restricted). This property is inherited from CIM_LogicalPort.

Unknown (0)

Front-end only (2)

Back-end only (3)

Not restricted (4 )

Requirements

Requirement Value
Minimum supported client
Windows 8 [desktop apps only]
Minimum supported server
Windows Server 2012 [desktop apps only]
Namespace
Root\Virtualization\V2
MOF
WindowsVirtualization.V2.mof
DLL
Vmms.exe