Įvykiai
04-09 15 - 04-10 12
Code the Future with AI and connect with Java peers and experts at JDConf 2025.
Registruotis dabarŠi naršyklė nebepalaikoma.
Atnaujinkite į „Microsoft Edge“, kad pasinaudotumėte naujausiomis funkcijomis, saugos naujinimais ir techniniu palaikymu.
This article provides troubleshooting guidance to help you resolve potential issues with devices that are running Windows 10 or newer and Windows Server 2016 or newer.
Microsoft Entra hybrid join supports the Windows 10 November 2015 update and later.
This article assumes that you have Microsoft Entra hybrid joined devices to support the following scenarios:
Pastaba
To troubleshoot the common device registration issues, use Device Registration Troubleshooter Tool.
dsregcmd /status
.+----------------------------------------------------------------------+
| Device State |
+----------------------------------------------------------------------+
AzureAdJoined: YES
EnterpriseJoined: NO
DeviceId: 5820fbe9-60c8-43b0-bb11-44aee233e4e7
Thumbprint: AA11BB22CC33DD44EE55FF66AA77BB88CC99DD00
KeyContainerId: bae6a60b-1d2f-4d2a-a298-33385f6d05e9
KeyProvider: Microsoft Platform Crypto Provider
TpmProtected: YES
KeySignTest: : MUST Run elevated to test.
Idp: login.windows.net
TenantId: aaaabbbb-0000-cccc-1111-dddd2222eeee
TenantName: Contoso
AuthCodeUrl: https://login.microsoftonline.com/msitsupp.microsoft.com/oauth2/authorize
AccessTokenUrl: https://login.microsoftonline.com/msitsupp.microsoft.com/oauth2/token
MdmUrl: https://enrollment.manage-beta.microsoft.com/EnrollmentServer/Discovery.svc
MdmTouUrl: https://portal.manage-beta.microsoft.com/TermsOfUse.aspx
dmComplianceUrl: https://portal.manage-beta.microsoft.com/?portalAction=Compliance
SettingsUrl: eyJVc{lots of characters}JdfQ==
JoinSrvVersion: 1.0
JoinSrvUrl: https://enterpriseregistration.windows.net/EnrollmentServer/device/
JoinSrvId: urn:ms-drs:enterpriseregistration.windows.net
KeySrvVersion: 1.0
KeySrvUrl: https://enterpriseregistration.windows.net/EnrollmentServer/key/
KeySrvId: urn:ms-drs:enterpriseregistration.windows.net
DomainJoined: YES
DomainName: CONTOSO
+----------------------------------------------------------------------+
| User State |
+----------------------------------------------------------------------+
NgcSet: YES
NgcKeyId: {aaaaaaaa-0b0b-1c1c-2d2d-333333333333}
WorkplaceJoined: NO
WamDefaultSet: YES
WamDefaultAuthority: organizations
WamDefaultId: https://login.microsoft.com
WamDefaultGUID: {B16898C6-A148-4967-9171-64D755DA8520} (AzureAd)
AzureAdPrt: YES
Review the fields in the following table, and make sure that they have the expected values:
Field | Expected value | Description |
---|---|---|
DomainJoined | YES | This field indicates whether the device is joined to an on-premises Active Directory. If the value is NO, the device can't do Microsoft Entra hybrid join. |
WorkplaceJoined | NO | This field indicates whether the device is registered with Microsoft Entra ID as a personal device (marked as Workplace Joined). This value should be NO for a domain-joined computer that's also Microsoft Entra hybrid joined. If the value is YES, a work or school account was added before the completion of the Microsoft Entra hybrid join. In this case, the account is ignored when you're using Windows 10 version 1607 or later. |
AzureAdJoined | YES | This field indicates whether the device is joined. The value is YES if the device is either a Microsoft Entra joined device or a Microsoft Entra hybrid joined device. If the value is NO, the join to Microsoft Entra ID hasn't finished yet. |
Continue to the next steps for further troubleshooting.
For Windows 10 version 1803 or later
Look for the "Previous Registration" subsection in the "Diagnostic Data" section of the join status output. This section is displayed only if the device is domain-joined and unable to Microsoft Entra hybrid join.
The "Error Phase" field denotes the phase of the join failure, and "Client ErrorCode" denotes the error code of the join operation.
+----------------------------------------------------------------------+
Previous Registration : 2019-01-31 09:16:43.000 UTC
Registration Type : sync
Error Phase : join
Client ErrorCode : 0x801c03f2
Server ErrorCode : DirectoryError
Server Message : The device object by the given id (e92325d0-xxxx-xxxx-xxxx-94ae875d5245) isn't found.
Https Status : 400
Request Id : 6bff0bd9-820b-484b-ab20-2a4f7b76c58e
+----------------------------------------------------------------------+
For earlier Windows 10 versions
Use Event Viewer logs to locate the phase and error code for the join failures.
Possible reasons for failure:
Possible reasons for failure:
https://enterpriseregistration.windows.net
, in the system context, to discover the registration and authorization endpoints.https://login.microsoftonline.com
, in the system context, to do realm discovery for the verified domain and determine the domain type (managed or federated).Common error codes:
Error code | Reason | Resolution |
---|---|---|
DSREG_AUTOJOIN_ADCONFIG_READ_FAILED (0x801c001d/-2145648611) | Unable to read the service connection point (SCP) object and get the Microsoft Entra tenant information. | Refer to the Configure a service connection point section. |
DSREG_AUTOJOIN_DISC_FAILED (0x801c0021/-2145648607) | Generic discovery failure. Failed to get the discovery metadata from the data replication service (DRS). | To investigate further, find the suberror in the next sections. |
DSREG_AUTOJOIN_DISC_WAIT_TIMEOUT (0x801c001f/-2145648609) | Operation timed out while performing discovery. | Ensure that https://enterpriseregistration.windows.net is accessible in the system context. For more information, see the Network connectivity requirements section. |
DSREG_AUTOJOIN_USERREALM_DISCOVERY_FAILED (0x801c003d/-2145648579) | Generic realm discovery failure. Failed to determine domain type (managed/federated) from STS. | To investigate further, find the suberror in the next sections. |
Common sub-error codes:
To find the suberror code for the discovery error code, use one of the following methods.
Look for "DRS Discovery Test" in the "Diagnostic Data" section of the join status output. This section is displayed only if the device is domain-joined and unable to Microsoft Entra hybrid join.
+----------------------------------------------------------------------+
| Diagnostic Data |
+----------------------------------------------------------------------+
Diagnostics Reference : www.microsoft.com/aadjerrors
User Context : UN-ELEVATED User
Client Time : 2019-06-05 08:25:29.000 UTC
AD Connectivity Test : PASS
AD Configuration Test : PASS
DRS Discovery Test : FAIL [0x801c0021/0x80072ee2]
DRS Connectivity Test : SKIPPED
Token acquisition Test : SKIPPED
Fallback to Sync-Join : ENABLED
+----------------------------------------------------------------------+
Use Event Viewer logs to look for the phase and error code for the join failures.
Network errors:
Error code | Reason | Resolution |
---|---|---|
WININET_E_CANNOT_CONNECT (0x80072efd/-2147012867) | Connection with the server couldn't be established. | Ensure network connectivity to the required Microsoft resources. For more information, see Network connectivity requirements. |
WININET_E_TIMEOUT (0x80072ee2/-2147012894) | General network timeout. | Ensure network connectivity to the required Microsoft resources. For more information, see Network connectivity requirements. |
WININET_E_DECODING_FAILED (0x80072f8f/-2147012721) | Network stack was unable to decode the response from the server. | Ensure that the network proxy isn't interfering and modifying the server response. |
HTTP errors:
Error code | Reason | Resolution |
---|---|---|
DSREG_DISCOVERY_TENANT_NOT_FOUND (0x801c003a/-2145648582) | The service connection point object is configured with the wrong tenant ID, or no active subscriptions were found in the tenant. | Ensure that the service connection point object is configured with the correct Microsoft Entra tenant ID and active subscriptions or that the service is present in the tenant. |
DSREG_SERVER_BUSY (0x801c0025/-2145648603) | HTTP 503 from DRS server. | The server is currently unavailable. Future join attempts will likely succeed after the server is back online. |
Other errors:
Error code | Reason | Resolution |
---|---|---|
E_INVALIDDATA (0x8007000d/-2147024883) | The server response JSON couldn't be parsed, likely because the proxy is returning an HTTP 200 with an HTML authorization page. | If the on-premises environment requires an outbound proxy, the IT admin must ensure that the system context on the device can discover and silently authenticate to the outbound proxy. |
This content applies only to federated domain accounts.
Reasons for failure:
Common error codes:
Use Event Viewer logs to locate the error code, suberror code, server error code, and server error message.
Configuration errors:
Error code | Reason | Resolution |
---|---|---|
ERROR_ADAL_PROTOCOL_NOT_SUPPORTED (0xcaa90017/-894894057) | The Azure AD Authentication Library (ADAL) authentication protocol isn't WS-Trust. | The on-premises identity provider must support WS-Trust. |
ERROR_ADAL_FAILED_TO_PARSE_XML (0xcaa9002c/-894894036) | The on-premises Federation Service didn't return an XML response. | Ensure that the Metadata Exchange (MEX) endpoint is returning a valid XML. Ensure that the proxy isn't interfering and returning nonxml responses. |
ERROR_ADAL_COULDNOT_DISCOVER_USERNAME_PASSWORD_ENDPOINT (0xcaa90023/-894894045) | Couldn't discover an endpoint for username/password authentication. | Check the on-premises identity provider settings. Ensure that the WS-Trust endpoints are enabled and that the MEX response contains these correct endpoints. |
Network errors:
Error code | Reason | Resolution |
---|---|---|
ERROR_ADAL_INTERNET_TIMEOUT (0xcaa82ee2/-894947614) | General network timeout. | Ensure that https://login.microsoftonline.com is accessible in the system context. Ensure that the on-premises identity provider is accessible in the system context. For more information, see Network connectivity requirements. |
ERROR_ADAL_INTERNET_CONNECTION_ABORTED (0xcaa82efe/-894947586) | Connection with the authorization endpoint was aborted. | Retry the join after a while, or try joining from another stable network location. |
ERROR_ADAL_INTERNET_SECURE_FAILURE (0xcaa82f8f/-894947441) | The Transport Layer Security (TLS) certificate (previously known as the Secure Sockets Layer [SSL] certificate) sent by the server couldn't be validated. | Check the client time skew. Retry the join after a while, or try joining from another stable network location. |
ERROR_ADAL_INTERNET_CANNOT_CONNECT (0xcaa82efd/-894947587) | The attempt to connect to https://login.microsoftonline.com failed. |
Check the network connection to https://login.microsoftonline.com . |
Other errors:
Error code | Reason | Resolution |
---|---|---|
ERROR_ADAL_SERVER_ERROR_INVALID_GRANT (0xcaa20003/-895352829) | The SAML token from the on-premises identity provider wasn't accepted by Microsoft Entra ID. | Check the Federation Server settings. Look for the server error code in the authentication logs. |
ERROR_ADAL_WSTRUST_REQUEST_SECURITYTOKEN_FAILED (0xcaa90014/-894894060) | The Server WS-Trust response reported a fault exception, and it failed to get assertion. | Check the Federation Server settings. Look for the server error code in the authentication logs. |
ERROR_ADAL_WSTRUST_TOKEN_REQUEST_FAIL (0xcaa90006/-894894074) | Received an error when trying to get access token from the token endpoint. | Look for the underlying error in the ADAL log. |
ERROR_ADAL_OPERATION_PENDING (0xcaa1002d/-895418323) | General ADAL failure. | Look for the suberror code or server error code from the authentication logs. |
Reasons for failure:
Look for the registration type and error code from the following tables, depending on the Windows 10 version you're using.
Look for the "Previous Registration" subsection in the "Diagnostic Data" section of the join status output. This section is displayed only if the device is domain-joined and is unable to Microsoft Entra hybrid join.
The "Registration Type" field denotes the type of join.
+----------------------------------------------------------------------+
Previous Registration : 2019-01-31 09:16:43.000 UTC
Registration Type : sync
Error Phase : join
Client ErrorCode : 0x801c03f2
Server ErrorCode : DirectoryError
Server Message : The device object by the given id (aaaaaaaa-0000-1111-2222-bbbbbbbbbbbb) is not found.
Https Status : 400
Request Id : 6bff0bd9-820b-484b-ab20-2a4f7b76c58e
+----------------------------------------------------------------------+
Use Event Viewer logs to locate the phase and error code for the join failures.
HTTP errors returned from DRS server:
Error code | Reason | Resolution |
---|---|---|
DSREG_E_DIRECTORY_FAILURE (0x801c03f2/-2145647630) | Received an error response from DRS with ErrorCode: "DirectoryError". | Refer to the server error code for possible reasons and resolutions. |
DSREG_E_DEVICE_AUTHENTICATION_ERROR (0x801c0002/-2145648638) | Received an error response from DRS with ErrorCode: "AuthenticationError" and ErrorSubCode is not "DeviceNotFound". | Refer to the server error code for possible reasons and resolutions. |
DSREG_E_DEVICE_INTERNALSERVICE_ERROR (0x801c0006/-2145648634) | Received an error response from DRS with ErrorCode: "DirectoryError". | Refer to the server error code for possible reasons and resolutions. |
TPM errors:
Error code | Reason | Resolution |
---|---|---|
NTE_BAD_KEYSET (0x80090016/-2146893802) | The Trusted Platform Module (TPM) operation failed or was invalid. | This error indicates that the keyset doesn't exist. This error happens when the TPM is cleared on the systems, or when there's a bad sysprep image. Avoid clearing the TPM in BIOS or Windows settings. If the TPM is cleared, users might need to recover by removing and readding accounts to fix the problem, especially when they have multiple WAM accounts. Ensure that the machine from which the sysprep image was created isn't Microsoft Entra joined, Microsoft Entra hybrid joined, or Microsoft Entra registered. |
TPM_E_PCP_INTERNAL_ERROR (0x80290407/-2144795641) | Generic TPM error. | Disable TPM on devices with this error. Windows 10 versions 1809 and later automatically detect TPM failures and complete Microsoft Entra hybrid join without using the TPM. |
TPM_E_NOTFIPS (0x80280036/-2144862154) | TPM in FIPS mode isn't currently supported. | Disable TPM on devices with this error. Windows 10 version 1809 automatically detects TPM failures and completes the Microsoft Entra hybrid join without using the TPM. |
NTE_AUTHENTICATION_IGNORED (0x80090031/-2146893775) | TPM is locked out. | Transient error. Wait for the cool-down period. The join attempt should succeed after a while. For more information, see TPM fundamentals. |
Network errors:
Error code | Reason | Resolution |
---|---|---|
WININET_E_TIMEOUT (0x80072ee2/-2147012894) | General network time out trying to register the device at DRS. | Check network connectivity to https://enterpriseregistration.windows.net . |
WININET_E_NAME_NOT_RESOLVED (0x80072ee7/-2147012889) | The server name or address couldn't be resolved. | Check network connectivity to https://enterpriseregistration.windows.net . |
WININET_E_CONNECTION_ABORTED (0x80072efe/-2147012866) | The connection with the server was terminated abnormally. | Retry the join after a while, or try joining from another stable network location. |
Other errors:
Error code | Reason | Resolution |
---|---|---|
DSREG_AUTOJOIN_ADCONFIG_READ_FAILED (0x801c001d/-2145648611) | Event ID 220 is present in User Device Registration event logs. Windows can't access the computer object in Active Directory. A Windows error code might be included in the event. Error codes ERROR_NO_SUCH_LOGON_SESSION (1312) and ERROR_NO_SUCH_USER (1317) are related to replication issues in on-premises Active Directory. | Troubleshoot replication issues in Active Directory. These replication issues might be transient, and they might go away after a while. |
Federated join server errors:
Server error code | Server error message | Possible reasons | Resolution |
---|---|---|---|
DirectoryError | Your request is throttled temporarily. Please try after 300 seconds. | This error is expected, possibly because multiple registration requests were made in quick succession. | Retry the join after the cool-down period |
Sync-join server errors:
Server error code | Server error message | Possible reasons | Resolution |
---|---|---|---|
DirectoryError | AADSTS90002: Tenant UUID not found. This error might happen if there are no active subscriptions for the tenant. Check with your subscription administrator. |
The tenant ID in the service connection point object is incorrect. | Ensure that the service connection point object is configured with the correct Microsoft Entra tenant ID and active subscriptions or that the service is present in the tenant. |
DirectoryError | The device object by the given ID isn't found. | This error is expected for sync-join. The device object hasn't synced from AD to Microsoft Entra ID | Wait for the Microsoft Entra Connect Sync to finish, and the next join attempt after sync completion will resolve the issue. |
AuthenticationError | The verification of the target computer's SID | The certificate on the Microsoft Entra device doesn't match the certificate used to sign in to the blob during the sync-join. This error ordinarily means that sync hasn't finished yet. | Wait for the Microsoft Entra Connect Sync to finish, and the next join attempt after the sync completion will resolve the issue. |
Extract the files to a folder, such as c:\temp, and then go to the folder.
From an elevated Azure PowerShell session, run .\start-auth.ps1 -v -accepteula
.
Select Switch Account to toggle to another session with the problem user.
Reproduce the issue.
Select Switch Account to toggle back to the admin session that's running the tracing.
From the elevated PowerShell session, run .\stop-auth.ps1
.
Zip (compress) and send the folder Authlogs from the folder where the scripts were executed.
Open a Command Prompt window.
Pastaba
To get the Primary Refresh Token (PRT) status, open the Command Prompt window in the context of the logged-in user.
Run dsregcmd /status
.
The "SSO state" section provides the current PRT status.
If the AzureAdPrt field is set to NO, there was an error acquiring the PRT status from Microsoft Entra ID.
If the AzureAdPrtUpdateTime is more than four hours, there's likely an issue with refreshing the PRT. Lock and unlock the device to force the PRT refresh, and then check to see whether the time updates.
+----------------------------------------------------------------------+
| SSO State |
+----------------------------------------------------------------------+
AzureAdPrt : YES
AzureAdPrtUpdateTime : 2020-07-12 22:57:53.000 UTC
AzureAdPrtExpiryTime : 2019-07-26 22:58:35.000 UTC
AzureAdPrtAuthority : https://login.microsoftonline.com/aaaabbbb-0000-cccc-1111-dddd2222eeee
EnterprisePrt : YES
EnterprisePrtUpdateTime : 2020-07-12 22:57:54.000 UTC
EnterprisePrtExpiryTime : 2020-07-26 22:57:54.000 UTC
EnterprisePrtAuthority : https://corp.hybridadfs.contoso.com:443/adfs
+----------------------------------------------------------------------+
From the dsregcmd
output
Pastaba
The output is available from the Windows 10 May 2021 update (version 21H1).
The "Attempt Status" field under the "AzureAdPrt" field provides the status of the previous PRT attempt, along with other required debug information. For earlier Windows versions, extract the information from the Microsoft Entra analytics and operational logs.
+----------------------------------------------------------------------+
| SSO State |
+----------------------------------------------------------------------+
AzureAdPrt : NO
AzureAdPrtAuthority : https://login.microsoftonline.com/aaaabbbb-0000-cccc-1111-dddd2222eeee
AcquirePrtDiagnostics : PRESENT
Previous Prt Attempt : 2020-07-18 20:10:33.789 UTC
Attempt Status : 0xc000006d
User Identity : john@contoso.com
Credential Type : Password
Correlation ID : aaaa0000-bb11-2222-33cc-444444dddddd
Endpoint URI : https://login.microsoftonline.com/aaaabbbb-0000-cccc-1111-dddd2222eeee/oauth2/token/
HTTP Method : POST
HTTP Error : 0x0
HTTP status : 400
Server Error Code : invalid_grant
Server Error Description : AADSTS50126: Error validating credentials due to invalid username or password.
From the Microsoft Entra analytics and operational logs
Use Event Viewer to look for the log entries logged by the Microsoft Entra CloudAP plug-in during PRT acquisition.
Pastaba
The CloudAP plug-in logs error events in the operational logs, and it logs the info events in the analytics logs. The analytics and operational log events are both required to troubleshoot issues.
Event 1006 in the analytics logs denotes the start of the PRT acquisition flow, and event 1007 in the analytics logs denotes the end of the PRT acquisition flow. All events in the Microsoft Entra logs (analytics and operational) that are logged between events 1006 and 1007 were logged as part of the PRT acquisition flow.
Event 1007 logs the final error code.
Error code | Reason | Resolution |
---|---|---|
STATUS_LOGON_FAILURE (-1073741715/ 0xc000006d) STATUS_WRONG_PASSWORD (-1073741718/ 0xc000006a) |
Note: WS-Trust is required for federated authentication. |
|
STATUS_REQUEST_NOT_ACCEPTED (-1073741616/ 0xc00000d0) | Received an error response (HTTP 400) from the Microsoft Entra authentication service or WS-Trust endpoint. Note: WS-Trust is required for federated authentication. |
Events 1081 and 1088 (Microsoft Entra operational logs) would contain the server error code and error description for errors originating from Microsoft Entra authentication service and WS-Trust endpoint, respectively. Common server error codes and their resolutions are listed in the next section. The first instance of event 1022 (Microsoft Entra analytics logs), preceding events 1081 or 1088, contain the URL that's being accessed. |
STATUS_NETWORK_UNREACHABLE (-1073741252/ 0xc000023c) STATUS_BAD_NETWORK_PATH (-1073741634/ 0xc00000be) STATUS_UNEXPECTED_NETWORK_ERROR (-1073741628/ 0xc00000c4) |
Note: WS-Trust is required for federated authentication. |
|
STATUS_NO_SUCH_LOGON_SESSION (-1073741729/ 0xc000005f) | User realm discovery failed because the Microsoft Entra authentication service was unable to find the user's domain. | |
AAD_CLOUDAP_E_OAUTH_USERNAME_IS_MALFORMED (-1073445812/ 0xc004844c) | The user's UPN isn't in the expected format. Notes: |
whoami /upn should display the configured UPN. |
AAD_CLOUDAP_E_OAUTH_USER_SID_IS_EMPTY (-1073445822/ 0xc0048442) | The user SID is missing in the ID token that's returned by the Microsoft Entra authentication service. | Ensure that the network proxy isn't interfering with and modifying the server response. |
AAD_CLOUDAP_E_WSTRUST_SAML_TOKENS_ARE_EMPTY (--1073445695/ 0xc00484c1) | Received an error from the WS-Trust endpoint. Note: WS-Trust is required for federated authentication. |
|
AAD_CLOUDAP_E_HTTP_PASSWORD_URI_IS_EMPTY (-1073445749/ 0xc004848b) | The MEX endpoint is incorrectly configured. The MEX response doesn't contain any password URLs. | |
AAD_CLOUDAP_E_HTTP_CERTIFICATE_URI_IS_EMPTY (-1073445748/ 0xc004848C) | The MEX endpoint is incorrectly configured. The MEX response doesn't contain any certificate endpoint URLs. | |
WC_E_DTDPROHIBITED (-1072894385/ 0xc00cee4f) | The XML response, from the WS-Trust endpoint, included a Document Type Definition (DTD). A DTD isn't expected in XML responses, and parsing the response fails if a DTD is included. Note: WS-Trust is required for federated authentication. |
Error code | Reason | Resolution |
---|---|---|
AADSTS50155: Device authentication failed | Follow the instructions for this issue in Microsoft Entra device management FAQ to re-register the device based on the device join type. | |
AADSTS50034: The user account Account does not exist in the tenant id directory |
Microsoft Entra ID is unable to find the user account in the tenant. | |
AADSTS50126: Error validating credentials due to invalid username or password. | To acquire a fresh PRT with the new credentials, wait for the Microsoft Entra password sync to finish. |
Error code | Reason | Resolution |
---|---|---|
ERROR_WINHTTP_TIMEOUT (12002) ERROR_WINHTTP_NAME_NOT_RESOLVED (12007) ERROR_WINHTTP_CANNOT_CONNECT (12029) ERROR_WINHTTP_CONNECTION_ERROR (12030) |
Common general network-related issues. | Get more network error codes. |
Pastaba
When you're collecting network traces, it's important to not use Fiddler during repro.
netsh trace start scenario=internetClient_dbg capture=yes persistent=yes
.netsh trace stop
.If you're connected to a mobile hotspot or an external Wi-Fi network and you go to Settings > Accounts > Access Work or School, Microsoft Entra hybrid joined devices might show two different accounts, one for Microsoft Entra ID and one for on-premises AD. This UI issue doesn't affect functionality.
Įvykiai
04-09 15 - 04-10 12
Code the Future with AI and connect with Java peers and experts at JDConf 2025.
Registruotis dabarMokymas
Modulis
Manage device authentication - Training
In this module, you will learn about device authentication and management in Microsoft Entra ID.
Sertifikatas
Microsoft Certified: Identity and Access Administrator Associate - Certifications
Demonstrate the features of Microsoft Entra ID to modernize identity solutions, implement hybrid solutions, and implement identity governance.