Lync Server 2013 中的 PurgeSettings 表 (QoE) PurgeSettings table (QoE) in Lync Server 2013

 

上次修改的主题: 2012-10-02Topic Last Modified: 2012-10-02

PurgeSettings 表包含指定是否(以及何时)将过时的用户体验质量记录从 QoE 数据库中自动删除。The PurgeSettings table contains information that specifies if (and when) outdated Quality of Experience records will automatically be deleted from the QoE database. 请注意,还可以通过运行以下命令,在 Microsoft Lync Server 2013 命令行管理程序中获取清除相关信息:Note that purging-related information can also be obtained from within the Microsoft Lync Server 2013 Management Shell by running the following command:

Get-CsQoEConfiguration

此表是在 Microsoft Lync Server 2013 中引入的。This table was introduced in Microsoft Lync Server 2013.

Column 数据类型Data Type 键/索引Key/Index DetailsDetails

IDID

intint

Primary

QoE 清除设置集合的唯一标识符。Unique identifier for the collection of QoE purge settings.

EnablePurgeEnablePurge

bit

如果设置为 True (1) Microsoft Lync Server 2013 将定期从 QoE 数据库中清除过期的记录。When set to True (1) Microsoft Lync Server 2013 will periodically purge outdated records from the QoE database. 将每天在 PurgeHour 设置所指定的时间执行清除。Purging will take place each day at the tome specified by the PurgeHour setting. 如果设置为 False (0),则不会从数据库中自动清除记录。If set to False (0) then records will not be automatically purged from the database. 默认值为 True。The default value is True.

KeepQoEDataForDaysKeepQoEDataForDays

intint

指定将从数据库中清除的 QoE 记录的保留时间(以天为单位):如果启用了清除,将从数据库中移除高于此值的 QoE 记录。默认值为 60 天。Specifies the age of QoE records (in days) that will be purged from the database: if purging is enabled, QoE records older than this value will be removed from the database. The default value is 60 days.

PurgeHourPurgeHour

intint

指定将执行数据库清除的本地时间。将采用 24 小时制指定时间,其中 0 表示午夜 (12:00 AM),23 表示 11:00 PM。请注意,您只能指定小时:允许值 10(指示 10:00 AM),但不允许值 10:30(即 10.5)(指示 10:30 AM)。默认值为 1 (1:00 AM)。Specifies the local time of day when database purging will take place. The time of day is specified using a 24-hour clock, with 0 representing midnight (12:00 AM) and 23 representing 11:00 PM. Note that you can only specify the hour of the day: a value of 10 (indicating 10:00 AM) is allowed, but a value of 10:30 of 10.5 (indicating 10:30 AM) is not allowed. The default value is 1 (1:00 AM). Specifies the local time of day when database purging will take place. The time of day is specified using a 24-hour clock, with 0 representing midnight (12:00 AM) and 23 representing 11:00 PM. Note that you can only specify the hour of the day: a value of 10 (indicating 10:00 AM) is allowed, but a value of 10:30 of 10.5 (indicating 10:30 AM) is not allowed. The default value is 1 (1:00 AM).