监视 Azure FXT Edge 文件服务器硬件状态Monitor Azure FXT Edge Filer hardware status

Azure FXT Edge 文件服务器混合存储缓存系统将多个状态灯内置于机箱,以帮助管理员了解硬件的工作方式。The Azure FXT Edge Filer hybrid storage cache system has multiple status lights built in to the chassis to help administrators understand how the hardware is functioning.

系统运行状况System health status

若要在更高级别上监视缓存操作,请使用 "软件控制面板" 的 "仪表板" 页,如控制面板的 "仪表板" 指南中所述To monitor cache operations at a higher level, use the software Control Panel's Dashboard page, as described in the Control Panel Dashboard Guide

硬件状态 LedHardware status LEDs

本部分介绍 Azure FXT Edge 文件服务器硬件中内置的各种状态灯。This section explains the various status lights built in to the Azure FXT Edge Filer hardware.

硬盘状态 LedHard drive status LEDs

硬盘正面,水平,带标注标签 2 (左上角) ,1 (左下角) ,3 (右端)

每个驱动器托架都有两个状态 Led:活动指示器 (1) ,状态指示器 (2) 。Each drive carrier has two status LEDs: an activity indicator (1) and a status indicator (2).

  • 使用该驱动器时,活动 LED (1) 灯亮起。The activity LED (1) lights when the drive is in use.
  • 状态 LED (2) 使用下表中的代码指示驱动器的状况。The status LED (2) indicates the condition of the drive by using the codes in the table below.
驱动器状态 LED 状态Drive status LED state 含义Meaning
每秒闪烁绿色两次Flashes green twice per second 正在识别驱动器 Identifying drive or
正在准备要删除的驱动器Preparing drive for removal
关闭 (unlit) Off (unlit) 系统尚未完成启动 System has not finished startup or
已准备好删除驱动器Drive is ready to be removed
闪烁绿色、琥珀色和熄灭Flashes green, amber, and off 预测驱动器故障Drive failure is predicted
每秒闪烁四次琥珀色Flashes amber four times per second 驱动器失败Drive failed
稳定绿色Solid green 驱动器处于联机状态Drive is online

驱动器 (3) 的右侧标有驱动器容量和其他信息。The right side of the drive (3) is labeled with the drive's capacity and other information.

驱动器编号显示在驱动器之间的空间上。Drive numbers are printed on the space between drives. 在 Azure FXT Edge Filer 中,驱动器 0 为左上角的驱动器,驱动器 1 位于其正下方。In the Azure FXT Edge Filer, drive 0 is the top left drive, and drive 1 is directly underneath it. 此模式中的编号继续。Numbering continues in that pattern.

FXT 机箱中一个硬盘槽的图片,其中显示了驱动器编号和容量标签

左侧控制面板Left control panel

左前控制面板的各种状态 LED 指示灯 (1) 和 (2) 的大型灯系统运行状况指示器。The left front control panel has various status LED indicators (1) and a large lighted system health indicator (2).

左侧状态面板,左侧有1个标签状态指示器,2则在右侧添加较大的系统健康指示器光源

控制面板状态指示器Control panel status indicators

如果系统中存在错误,则左侧的状态指示器显示稳定的琥珀色指示灯。The status indicators at left show a solid amber light if there is an error in that system. 下表描述了可能的错误原因和解决方法。The table below describes possible causes and solutions for the errors.

如果尝试这些解决方案后仍出现错误,请 联系支持人员 获取帮助。If you still have the error after trying these solutions, contact support for help.

图标Icon 描述Description 添加状态Error condition 可能的解决方案Possible solutions
驱动器图标 驱动器状态Drive status 驱动器错误Drive error 检查系统事件日志以确定驱动器是否有错误,或Check the System Event Log to determine if the drive has an error, or
运行相应的联机诊断测试;重新启动系统并运行嵌入诊断 (ePSA) ,或Run the appropriate online diagnostics test; restart the system and run embedded diagnostics (ePSA), or
如果驱动器是在 RAID 阵列中配置的,请重新启动系统并输入主机适配器配置实用程序If the drives are configured in a RAID array, restart the system and enter the host adapter configuration utility program
温度图标 温度状态Temperature status 温度错误-例如,风扇出现故障或环境温度超出范围Thermal error - for example, a fan has failed or ambient temperature is out of range 检查以下可寻址条件:Check for the following addressable conditions:
冷却风扇丢失或已失败A cooling fan is missing or has failed
系统盖、导风槽、内存模块为空或背面填充托架已删除The system's cover, air shroud, memory module blank, or back filler bracket is removed
环境温度过高The ambient temperature is too high
外部气流受到阻碍External airflow is obstructed
电力图标 电气状态Electrical status 电气错误-例如,电压超出范围、失败的 PSU 或发生故障的电压调节器Electrical error - for example, voltage out of range, failed PSU, or a failed voltage regulator 检查系统事件日志或系统消息中是否有特定的问题。Check the system event log or system messages for the specific issue. 如果出现 PSU 问题,请检查 PSU 状态 LED,并根据需要重新拔插 PSU。If there is a PSU problem, check the PSU status LED and reseat the PSU if needed.
内存图标 内存状态Memory status 内存错误Memory error 检查系统事件日志或系统消息中是否有失败的内存;重新拔插内存模块。Check the system event log or system messages for the location of the failed memory; reseat the memory module.
PCIe 图标 PCIe 状态PCIe status PCIe 卡错误PCIe card error 重新启动系统;更新 PCIe 卡驱动程序;重新安装卡Restart the system; update PCIe card drivers; reinstall the card

系统运行状况状态指示器System health status indicator

左侧控制面板右侧的 "大点" 按钮指示整体系统状态,并且在系统 ID 模式下用作单元定位灯。The large lit button at the right of the left control panel indicates overall system status and also is used as a unit locator light in system ID mode.

按 "系统运行状况" 和 "ID" 按钮在系统 ID 模式和系统运行状况模式间切换。Press the system health and ID button to switch between system ID mode and system health mode.

系统运行状况状态System health status state 条件Condition
稳定蓝色Solid blue 正常操作:系统已打开,正常运行,系统 ID 模式处于非活动状态。Normal operation: the system is turned on, operating normally, and system ID mode is not active.
如果要切换到系统 ID 模式,请按 "系统运行状况" 和 "ID" 按钮。Press the system health and ID button if you want to switch to system ID mode.
蓝色闪烁Blinking blue 系统 ID 模式处于活动状态。System ID mode is active. 如果要切换到系统运行状况模式,请按 "系统运行状况和系统 ID" 按钮。Press the system health and system ID button if you want to switch to system health mode.
稳定琥珀色Solid amber 系统处于故障安全模式。The system is in fail-safe mode. 如果问题仍然存在,请 与 Microsoft 客户服务和支持联系If the problem persists, contact Microsoft Customer Service and Support.
琥珀色闪烁Blinking amber 系统错误。System fault. 检查系统事件日志中是否有特定的错误消息。Check the system event log for specific error messages. 有关系统固件和监视系统组件的代理生成的事件和错误消息的信息,请参阅错误代码查找页面,网址为 qrl.dell.com。For information about the event and error messages generated by the system firmware and agents that monitor system components, see the Error Code Lookup page at qrl.dell.com.