Ddv4 和 Ddsv4 系列Ddv4 and Ddsv4-series

Ddv4 和 Ddsv4 系列采用英特尔® 至强® 铂金 8272CL (Cascade Lake) 处理器,具有超线程配置,为大多数通用工作负载提供了更好的价值主张。The Ddv4 and Ddsv4-series runs on the Intel® Xeon® Platinum 8272CL (Cascade Lake) processors in a hyper-threaded configuration, providing a better value proposition for most general-purpose workloads. 它具有 3.4 GHz、 intel ® 迅迅技术 2.0Intel ® Hyper-Threading 技术intel ® 高级矢量扩展 512 (Intel ® AVX-512) 的所有核心 Turbo 时钟速度。It features an all core Turbo clock speed of 3.4 GHz, Intel® Turbo Boost Technology 2.0, Intel® Hyper-Threading Technology and Intel® Advanced Vector Extensions 512 (Intel® AVX-512). 它们还支持 Intel® Deep Learning BoostThey also support Intel® Deep Learning Boost. Gen2 VMDv3/Dsv3 大小相比,这些新的 VM 大小的本地存储将增加 50%,而且本地磁盘的读写 IOPS 更佳。These new VM sizes will have 50% larger local storage, as well as better local disk IOPS for both read and write compared to the Dv3/Dsv3 sizes with Gen2 VMs.

D 系列用例包括企业级应用程序、关系数据库、内存中缓存和分析。D-series use cases include enterprise-grade applications, relational databases, in-memory caching, and analytics.

Ddv4 系列Ddv4-series

Ddv4 系列大小采用英特尔® 至强® 铂金 8272CL (Cascade Lake) 处理器。Ddv4-series sizes run on the Intel® Xeon® Platinum 8272CL (Cascade Lake). Ddv4 系列提供 vCPU、内存和临时磁盘的组合,适用于大多数生产工作负载。The Ddv4-series offer a combination of vCPU, memory and temporary disk for most production workloads.

新的 Ddv4 VM 大小包括一个快速、大型本地 SSD 存储(多达 2,400 GiB),适用于需要低延迟、高速本地存储的应用程序,例如,适用于需要快速读取/写入临时存储或需要临时存储才能存储缓存或临时文件的应用程序。The new Ddv4 VM sizes include fast, larger local SSD storage (up to 2,400 GiB) and are designed for applications that benefit from low latency, high-speed local storage, such as applications that require fast reads/ writes to temp storage or that need temp storage for caches or temporary files. 可以将标准 SSD 和标准 HDD 存储附加到 Ddv4 VM。You can attach Standard SSDs and Standard HDDs storage to the Ddv4 VMs. 远程数据磁盘存储与虚拟机分开计费。Remote Data disk storage is billed separately from virtual machines.

ACU:195-210ACU: 195-210
高级存储:不支持Premium Storage: Not Supported
高级存储缓存:不支持Premium Storage caching: Not Supported
实时迁移:支持Live Migration: Supported
内存保留更新:受支持Memory Preserving Updates: Supported
VM 生成支持:第1代和第2代VM Generation Support: Generation 1 and 2

大小Size vCPUvCPU 内存:GiBMemory: GiB 临时存储 (SSD) GiBTemp storage (SSD) GiB 最大数据磁盘数Max data disks ** 缓存和临时存储的最大吞吐量: IOPS/MBps** Max cached and temp storage throughput: IOPS/MBps 最大 NIC 数Max NICs 预期的网络带宽 (Mbps)Expected Network bandwidth (Mbps)
Standard_D2d_v4Standard_D2d_v4 22 88 7575 44 19000/12019000/120 22 10001000
Standard_D4d_v4Standard_D4d_v4 44 1616 150150 88 38500/24238500/242 22 20002000
Standard_D8d_v4Standard_D8d_v4 88 3232 300300 1616 77000/48577000/485 44 40004000
Standard_D16d_v4Standard_D16d_v4 1616 6464 600600 3232 154000/968154000/968 88 80008000
Standard_D32d_v4Standard_D32d_v4 3232 128128 12001200 3232 308000/1936308000/1936 88 1600016000
Standard_D48d_v4Standard_D48d_v4 4848 192192 18001800 3232 462000/2904462000/2904 88 2400024000
Standard_D64d_v4Standard_D64d_v4 6464 256256 24002400 3232 615000/3872615000/3872 88 3000030000

**可以通过使用Gen2 vm来保证这些 IOPs 值** These IOPs values can be guaranteed by using Gen2 VMs

Ddsv4 系列Ddsv4-series

Ddsv4 系列采用英特尔® 至强® 铂金 8272CL (Cascade Lake) 处理器。Ddsv4-series run on the Intel® Xeon® Platinum 8272CL (Cascade Lake). Ddsv4 系列提供 vCPU、内存和临时磁盘的组合,适用于大多数生产工作负载。The Ddsv4-series offer a combination of vCPU, memory and temporary disk for most production workloads.

新的 Ddsv4 VM 大小包括一个快速、大型本地 SSD 存储(多达 2,400 GiB),适用于需要低延迟、高速本地存储的应用程序,例如,适用于需要快速读取/写入临时存储或需要临时存储才能存储缓存或临时文件的应用程序。The new Ddsv4 VM sizes include fast, larger local SSD storage (up to 2,400 GiB) and are designed for applications that benefit from low latency, high-speed local storage, such as applications that require fast reads/ writes to temp storage or that need temp storage for caches or temporary files.

备注

Ddsv4 大小的定价和计费标准与 Ddv4 系列相同。The pricing and billing meters for Ddsv4 sizes are the same as Ddv4-series.

ACU:195-210ACU: 195-210
高级存储:受支持Premium Storage: Supported
高级存储缓存:支持Premium Storage caching: Supported
实时迁移:支持Live Migration: Supported
内存保留更新:受支持Memory Preserving Updates: Supported
VM 生成支持:第1代和第2代VM Generation Support: Generation 1 and 2

大小Size vCPUvCPU 内存:GiBMemory: GiB 临时存储 (SSD) GiBTemp storage (SSD) GiB 最大数据磁盘数Max data disks ** 缓存和临时存储的最大吞吐量: IOPS/MBps (GiB 中的缓存大小) ** Max cached and temp storage throughput: IOPS/MBps (cache size in GiB) 最大非缓存磁盘吞吐量:IOPS/MBpsMax uncached disk throughput: IOPS/MBps 最大 NIC 数Max NICs 预期的网络带宽 (Mbps)Expected Network bandwidth (Mbps)
Standard_D2ds_v4Standard_D2ds_v4 22 88 7575 44 19000/120(50)19000/120(50) 3200/483200/48 22 10001000
Standard_D4ds_v4Standard_D4ds_v4 44 1616 150150 88 38500/242(100)38500/242(100) 6400/966400/96 22 20002000
Standard_D8ds_v4Standard_D8ds_v4 88 3232 300300 1616 77000/485(200)77000/485(200) 12800/19212800/192 44 40004000
Standard_D16ds_v4Standard_D16ds_v4 1616 6464 600600 3232 154000/968(400)154000/968(400) 25600/38425600/384 88 80008000
Standard_D32ds_v4Standard_D32ds_v4 3232 128128 12001200 3232 308000/1936(800)308000/1936(800) 51200/76851200/768 88 1600016000
Standard_D48ds_v4Standard_D48ds_v4 4848 192192 18001800 3232 462000/2904(1200)462000/2904(1200) 76800/115276800/1152 88 2400024000
Standard_D64ds_v4Standard_D64ds_v4 6464 256256 24002400 3232 615000/3872(1600)615000/3872(1600) 80000/120080000/1200 88 3000030000

**可以通过使用Gen2 vm来保证这些 IOPs 值** These IOPs values can be guaranteed by using Gen2 VMs

大小表定义Size table definitions

  • 存储容量的单位为 GiB 或 1024^3 字节。Storage capacity is shown in units of GiB or 1024^3 bytes. 比较以 GB(1000^3 字节)为单位的磁盘与以 GiB(1024^3 字节)为单位的磁盘时,请记住以 GiB 为单位的容量数显得更小。When you compare disks measured in GB (1000^3 bytes) to disks measured in GiB (1024^3) remember that capacity numbers given in GiB may appear smaller. 例如,1023 GiB = 1098.4 GB。For example, 1023 GiB = 1098.4 GB.

  • 磁盘吞吐量的单位为每秒输入/输出操作数 (IOPS) 和 MBps,其中 MBps = 10^6 字节/秒。Disk throughput is measured in input/output operations per second (IOPS) and MBps where MBps = 10^6 bytes/sec.

  • 数据磁盘可以在缓存或非缓存模式下运行。Data disks can operate in cached or uncached modes. 对于缓存数据磁盘操作,主机缓存模式设置为 ReadOnlyReadWriteFor cached data disk operation, the host cache mode is set to ReadOnly or ReadWrite. 对于非缓存数据磁盘操作,主机缓存模式设置为 NoneFor uncached data disk operation, the host cache mode is set to None.

  • 若要获得 VM 的最佳性能,应将数据磁盘数限制为每 vCPU 2 个磁盘。If you want to get the best performance for your VMs, you should limit the number of data disks to two disks per vCPU.

  • 预期的网络带宽是指跨所有 NIC 为每个 VM 类型分配的最大聚合带宽,适用于所有目标。Expected network bandwidth is the maximum aggregated bandwidth allocated per VM type across all NICs, for all destinations. 有关详细信息,请参阅虚拟机网络带宽For more information, see Virtual machine network bandwidth.

    无法保证上限。Upper limits aren't guaranteed. 限值用于在为目标应用程序选择适当的 VM 类型时提供指导。Limits offer guidance for selecting the right VM type for the intended application. 实际的网络性能将取决于多种因素,包括网络拥塞、应用程序负载和网络设置。Actual network performance will depend on several factors including network congestion, application loads, and network settings. 有关如何优化网络吞吐量的信息,请参阅为 Azure 虚拟机优化网络吞吐量For information on optimizing network throughput, see Optimize network throughput for Azure virtual machines. 若要在 Linux 或 Windows 中达到预期的网络性能,可能需要选择特定版本,或者需要优化 VM。To achieve the expected network performance on Linux or Windows, you may need to select a specific version or optimize your VM. 有关详细信息,请参阅带宽/吞吐量测试 (NTTTCP)For more information, see Bandwidth/Throughput testing (NTTTCP).

其他大小和信息Other sizes and information

定价计算器:定价计算器Pricing Calculator: Pricing Calculator

有关磁盘类型的详细信息:磁盘类型More information on Disks Types : Disk Types

后续步骤Next steps

了解有关 Azure 计算单元 (ACU) 如何帮助跨 Azure SKU 比较计算性能的详细信息。Learn more about how Azure compute units (ACU) can help you compare compute performance across Azure SKUs.